Determination of chlorogenic acid and rutin in Ainsliaea fragrans by RP-HPLC with gradient elution
Zheng Zhao-yu
Abstract
Zheng Zhao-yu
Abstract
A method for simultaneous determination of chlorogenic acid and rutin in Ainsliaea fragrans from different resources was established.A kromasil C18(4.6 mm×250 mm,5 μm) column was used with a mobile phase consisted of phase A (methanol)-phase B(0.5% phosphoric acid water solution) in gradient elution 0 min(30∶70)-15 min(30∶70)-20 min(50∶50)-40 min(50∶50) at a flow rate of 0.8 mL/min in this method,the detection wavelength was set at 350 nm and the column temperature was 25 ℃.Photodiode array detector was used.The calibration curve was linear in a range of 0.654~5.886 μg for chlorogenic acid(r=0.9997).The average recovery was 98.6% and RSD was 1.7%(n=6).The calibration curve was linear in a range of 0.109~0.981 μg for rutin(r=0.9993).The average recovery was 97.1% and RSD was 2.3%(n=6).This method is rapid,simple and reproducible.It can be used as a quality control method for rutin and chlorogenic acid in Ainsliaea fragrans.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A method for simultaneous determination of chlorogenic acid and rutin in Ainsliaea fragrans from different resources was established.A kromasil C18(4.6 mm×250 mm,5 μm) column was used with a mobile phase consisted of phase A (methanol)-phase B(0.5% phosphoric acid water solution) in gradient elution 0 min(30∶70)-15 min(30∶70)-20 min(50∶50)-40 min(50∶50) at a flow rate of 0.8 mL/min in this method,the detection wavelength was set at 350 nm and the column temperature was 25 ℃.Photodiode array detector was used.The calibration curve was linear in a range of 0.654~5.886 μg for chlorogenic acid(r=0.9997).The average recovery was 98.6% and RSD was 1.7%(n=6).The calibration curve was linear in a range of 0.109~0.981 μg for rutin(r=0.9993).The average recovery was 97.1% and RSD was 2.3%(n=6).This method is rapid,simple and reproducible.It can be used as a quality control method for rutin and chlorogenic acid in Ainsliaea fragrans.
Key concepts: Chlorogenic acid, Chemistry, Rutin, Chromatography, Phosphoric acid, Calibration curve, High-performance liquid chromatography, Gradient elution