2013Journal of Clinical Pulmonary MedicineRequires access

Value of multi-layer spiral dynamic enhanced CT scan in solitary pulmonary nodule

Wensheng Wang

Open publisher page 0 citations

Abstract

Objective To explore the value of dynamic enhanced multi-layer CT scan in solitary pulmonary nodule.Methods 60 patients with signle solitary pulmonary nodules were chosen to give dynamic ehchanced multi-layer spiral CT scan.The change of CT value and the pathological results were analyzed.Results The CT values of enhanced scan were obviously higher in the malignant group than the benign group with statistical significance(P 0.05).The change of CT value equal or more than 20HU was considered to have malignant nodules,and the change less than 20HU diagnosed as benign nodules.There was no significant difference of diagnosis resluts between enhanced CT scan and pathological diagnosis on solitary nodule(χ2 = 1.40,P 0.05).Conclusion Mult-layer spiral enhanced CT scan has a high application value in the differential diagnosis of patients with benign or malignant nodules.

About this research paper

What this paper is about

Objective To explore the value of dynamic enhanced multi-layer CT scan in solitary pulmonary nodule.Methods 60 patients with signle solitary pulmonary nodules were chosen to give dynamic ehchanced multi-layer spiral CT scan.The change of CT value and the pathological results were analyzed.Results The CT values of enhanced scan were obviously higher in the malignant group than the benign group with statistical significance(P 0.05).The change of CT value equal or more than 20HU was considered to have malignant nodules,and the change less than 20HU diagnosed as benign nodules.There was no significant difference of diagnosis resluts between enhanced CT scan and pathological diagnosis on solitary nodule(χ2 = 1.40,P 0.05).Conclusion Mult-layer spiral enhanced CT scan has a high application value in the differential diagnosis of patients with benign or malignant nodules.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To explore the value of dynamic enhanced multi-layer CT scan in solitary pulmonary nodule.Methods 60 patients with signle solitary pulmonary nodules were chosen to give dynamic ehchanced multi-layer spiral CT scan.The change of CT value and the pathological results were analyzed.Results The CT values of enhanced scan were obviously higher in the malignant group than the benign group with statistical significance(P 0.05).The change of CT value equal or more than 20HU was considered to have malignant nodules,and the change less than 20HU diagnosed as benign nodules.There was no significant difference of diagnosis resluts between enhanced CT scan and pathological diagnosis on solitary nodule(χ2 = 1.40,P 0.05).Conclusion Mult-layer spiral enhanced CT scan has a high application value in the differential diagnosis of patients with benign or malignant nodules.

Key concepts: Medicine, Solitary pulmonary nodule, Nodule (geology), Pathological, Radiology, Differential diagnosis, Significant difference, Computed tomography

Related papers

Back to paper searchBrowse research topicsOriginal source
Value of multi-layer spiral dynamic enhanced CT scan in solitary pulmonary nodule — Research Paper | ScholarLens