2012China Water & WastewaterRequires access

Determination of Chlorpyrifos in Drinking Water by Solid-phase Extraction and Gas Chromatography-Mass Spectrometry

Ying Ma

Open publisher page 0 citations

Abstract

An analytical method for determination of chlorpyrifos in drinking water by solid-phase extraction(SPE) and GC-MS was developed.The detection limit of chlorpyrifos was 0.000 6 mg/L,which was much lower than the national standard method of 0.002 mg/L.The linear range was 0.5 to 5.0 mg/L,the spiked recovery was 74.86% to 86.14%,and the relative standard deviation(RSD) was less than 5.4%.The method is simple,sensitive,accurate and reproducible,and it is suitable for determination of trace chlorpyrifos in water.

About this research paper

What this paper is about

An analytical method for determination of chlorpyrifos in drinking water by solid-phase extraction(SPE) and GC-MS was developed.The detection limit of chlorpyrifos was 0.000 6 mg/L,which was much lower than the national standard method of 0.002 mg/L.The linear range was 0.5 to 5.0 mg/L,the spiked recovery was 74.86% to 86.14%,and the relative standard deviation(RSD) was less than 5.4%.The method is simple,sensitive,accurate and reproducible,and it is suitable for determination of trace chlorpyrifos in water.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An analytical method for determination of chlorpyrifos in drinking water by solid-phase extraction(SPE) and GC-MS was developed.The detection limit of chlorpyrifos was 0.000 6 mg/L,which was much lower than the national standard method of 0.002 mg/L.The linear range was 0.5 to 5.0 mg/L,the spiked recovery was 74.86% to 86.14%,and the relative standard deviation(RSD) was less than 5.4%.The method is simple,sensitive,accurate and reproducible,and it is suitable for determination of trace chlorpyrifos in water.

Key concepts: Chlorpyrifos, Solid phase extraction, Chromatography, Detection limit, Chemistry, Extraction (chemistry), Gas chromatography–mass spectrometry, Mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Chlorpyrifos in Drinking Water by Solid-phase Extraction and Gas Chromatography-Mass Spectrometry — Research Paper | ScholarLens