Determination of chlorpyrifos and chlorpyrifos-methyl in water by gas chromatography-μ-electron capture detector(GC-μECD)
Ji Ping
Abstract
Ji Ping
Abstract
Objective:To establish a method for determination of chlorpyrifos and chlorpyrifos-methyl in water by gas chromatography-μ-electron capture detector(GC-μECD).Methods:Chlorpyrifos and chlorpyrifos-methyl in water were extracted with petroleum ether or cyclohexane.The analysis was performed by gas chromatography-μ-electron capture detector(GC-μECD).Retention times were used to confirm the pesticides.Results:The calibration curves of chlorpyrifos and chlorpyrifos-methyl were linear(correlatiom coefficient r0.999) within the range of 0.001 μg/ml~300 μg/ml,respectively.The recoveries were ranged from 93.2%~108% and 96.3%~103%,respectively.The relative standard deviations(RSD) of the method was 5%(n=8) for each case,and the limit of determination(LOD) was 0.5 μg/L.Conclusion:The method is simple,rapid.Its sensitivity and selectivity are high.The method is suitable for determining of chlorpyrifos and chlorpyrifos-methyl in water.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To establish a method for determination of chlorpyrifos and chlorpyrifos-methyl in water by gas chromatography-μ-electron capture detector(GC-μECD).Methods:Chlorpyrifos and chlorpyrifos-methyl in water were extracted with petroleum ether or cyclohexane.The analysis was performed by gas chromatography-μ-electron capture detector(GC-μECD).Retention times were used to confirm the pesticides.Results:The calibration curves of chlorpyrifos and chlorpyrifos-methyl were linear(correlatiom coefficient r0.999) within the range of 0.001 μg/ml~300 μg/ml,respectively.The recoveries were ranged from 93.2%~108% and 96.3%~103%,respectively.The relative standard deviations(RSD) of the method was 5%(n=8) for each case,and the limit of determination(LOD) was 0.5 μg/L.Conclusion:The method is simple,rapid.Its sensitivity and selectivity are high.The method is suitable for determining of chlorpyrifos and chlorpyrifos-methyl in water.
Key concepts: Chlorpyrifos, Chemistry, Chromatography, Electron capture detector, Gas chromatography, Detection limit, Pesticide, Biology