2011•Gas & HeatRequires access

Problems and Solutions Concerning Cathodic Protection in Oil and Gas Transmission Station

Sun Jianmi

Open publisher page 2 citations

Abstract

The technical characteristics of cathodic protection (CP) in oil and gas transmission station are introduced. Some problems such as high consumption of CP current,unreasonable distribution of anode ground bed,interference and shielding in design,construction and operation commissioning of cathodic protection system in a practical station are analyzed,and corresponding solutions are put forward. The simulation method of CP potential distribution values is used in design of CP in the station, and the relative error between the value calculation result and the practical measurement result is less than 5% .

About this research paper

What this paper is about

The technical characteristics of cathodic protection (CP) in oil and gas transmission station are introduced. Some problems such as high consumption of CP current,unreasonable distribution of anode ground bed,interference and shielding in design,construction and operation commissioning of cathodic protection system in a practical station are analyzed,and corresponding solutions are put forward. The simulation method of CP potential distribution values is used in design of CP in the station, and the relative error between the value calculation result and the practical measurement result is less than 5% .

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The technical characteristics of cathodic protection (CP) in oil and gas transmission station are introduced. Some problems such as high consumption of CP current,unreasonable distribution of anode ground bed,interference and shielding in design,construction and operation commissioning of cathodic protection system in a practical station are analyzed,and corresponding solutions are put forward. The simulation method of CP potential distribution values is used in design of CP in the station, and the relative error between the value calculation result and the practical measurement result is less than 5% .

Key concepts: Cathodic protection, Ground, Electromagnetic shielding, Transmission (telecommunications), Electrical engineering, Interference (communication), Anode, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Problems and Solutions Concerning Cathodic Protection in Oil and Gas Transmission Station — Research Paper | ScholarLens