2015Corrosion & ProtectionRequires access

Detection and Handing of Interference Between Regional Cathodic Protection and Line Cathodic Protection in a Typical Station

Fang Wei-li

Open publisher page 0 citations

Abstract

In order to eliminate the interference of regional cathodic protection system to line cathodic protection system,make the line cathodic protection system normally operate with constant potentials,numerical simulation of cathodic protection potential distribution and interference simulation calculation of three-dimensional geometric model were used to analyze the interference,and the simulation was verified by field test.The interference was managed effectively through the results of simulation and field test,the interference between regional cathodic protection system and line cathodic protection system was elimited,the output parameters of line constant potential rectifier were recovered to the level before interference.

About this research paper

What this paper is about

In order to eliminate the interference of regional cathodic protection system to line cathodic protection system,make the line cathodic protection system normally operate with constant potentials,numerical simulation of cathodic protection potential distribution and interference simulation calculation of three-dimensional geometric model were used to analyze the interference,and the simulation was verified by field test.The interference was managed effectively through the results of simulation and field test,the interference between regional cathodic protection system and line cathodic protection system was elimited,the output parameters of line constant potential rectifier were recovered to the level before interference.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to eliminate the interference of regional cathodic protection system to line cathodic protection system,make the line cathodic protection system normally operate with constant potentials,numerical simulation of cathodic protection potential distribution and interference simulation calculation of three-dimensional geometric model were used to analyze the interference,and the simulation was verified by field test.The interference was managed effectively through the results of simulation and field test,the interference between regional cathodic protection system and line cathodic protection system was elimited,the output parameters of line constant potential rectifier were recovered to the level before interference.

Key concepts: Cathodic protection, Interference (communication), Line (geometry), Electromagnetic interference, Electrical engineering, Anode, Engineering, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Detection and Handing of Interference Between Regional Cathodic Protection and Line Cathodic Protection in a Typical Station — Research Paper | ScholarLens