2005Yaowu fenxi zazhiRequires access

RP-HPLC Determination of Secutellarin in Erigeron breviscapus(Vant.)Hand.-Mazz.

BI Kai-shun

Open publisher page 0 citations

Abstract

Objective:To determine secutellarin in Erigeron breviscapus with RP-HPLC.Method:ODS 2 column (200mm×4.6mm,5μm)was used.The mobil phase consisted of aeetontrile-water-THF-H_3PO_4(15:85:1.5 :0.1),flow of rate:0.8mL·min~(-1) and temperature of column 30℃ and detected at 335 nm.Result:The linear range was 2.16-34.5μg·mL~(-1)for secutellarin.The method recoveries were 96.9%-97.5%,and the relative standard deviations were 1.5%-2.4%.Conclusion:This method is simple and can be used to determine secutel- latin with satisfactory accuracy and reproducibility.

About this research paper

What this paper is about

Objective:To determine secutellarin in Erigeron breviscapus with RP-HPLC.Method:ODS 2 column (200mm×4.6mm,5μm)was used.The mobil phase consisted of aeetontrile-water-THF-H_3PO_4(15:85:1.5 :0.1),flow of rate:0.8mL·min~(-1) and temperature of column 30℃ and detected at 335 nm.Result:The linear range was 2.16-34.5μg·mL~(-1)for secutellarin.The method recoveries were 96.9%-97.5%,and the relative standard deviations were 1.5%-2.4%.Conclusion:This method is simple and can be used to determine secutel- latin with satisfactory accuracy and reproducibility.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To determine secutellarin in Erigeron breviscapus with RP-HPLC.Method:ODS 2 column (200mm×4.6mm,5μm)was used.The mobil phase consisted of aeetontrile-water-THF-H_3PO_4(15:85:1.5 :0.1),flow of rate:0.8mL·min~(-1) and temperature of column 30℃ and detected at 335 nm.Result:The linear range was 2.16-34.5μg·mL~(-1)for secutellarin.The method recoveries were 96.9%-97.5%,and the relative standard deviations were 1.5%-2.4%.Conclusion:This method is simple and can be used to determine secutel- latin with satisfactory accuracy and reproducibility.

Key concepts: Chemistry, Chromatography, Reproducibility, High-performance liquid chromatography, Relative standard deviation, Linear range, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
RP-HPLC Determination of Secutellarin in Erigeron breviscapus(Vant.)Hand.-Mazz. — Research Paper | ScholarLens