2008Chinese Journal of Public Health EngineeringRequires access

Determination of Total Mercury in Air by Atomic Fluorescence Spectrometry

XU Yue-hu

Open publisher page 0 citations

Abstract

ObjectiveTo establish a method for detection of total mercury in air.MethodsTotal mercury in air was absorbed,gathered,oxidized by potassium permanganate liquid,and determined by atomic fluorescence spectrometry.ResultsThe detection limit was 0.02 ng/ml,the linear range was 0-30 ng/ml,r=0.999 6,RSD was 2.3%-4.5%,the recovery rate was 90.0%-98.0%.There was no significant difference between the results obtained by two methods(t=0.14,P0.05).ConclusionThis method is simple,quick,accurate and sensitive.

About this research paper

What this paper is about

ObjectiveTo establish a method for detection of total mercury in air.MethodsTotal mercury in air was absorbed,gathered,oxidized by potassium permanganate liquid,and determined by atomic fluorescence spectrometry.ResultsThe detection limit was 0.02 ng/ml,the linear range was 0-30 ng/ml,r=0.999 6,RSD was 2.3%-4.5%,the recovery rate was 90.0%-98.0%.There was no significant difference between the results obtained by two methods(t=0.14,P0.05).ConclusionThis method is simple,quick,accurate and sensitive.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

ObjectiveTo establish a method for detection of total mercury in air.MethodsTotal mercury in air was absorbed,gathered,oxidized by potassium permanganate liquid,and determined by atomic fluorescence spectrometry.ResultsThe detection limit was 0.02 ng/ml,the linear range was 0-30 ng/ml,r=0.999 6,RSD was 2.3%-4.5%,the recovery rate was 90.0%-98.0%.There was no significant difference between the results obtained by two methods(t=0.14,P0.05).ConclusionThis method is simple,quick,accurate and sensitive.

Key concepts: Mercury (programming language), Potassium permanganate, Detection limit, Chemistry, Linear range, Recovery rate, Mass spectrometry, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Total Mercury in Air by Atomic Fluorescence Spectrometry — Research Paper | ScholarLens