2012Food Science and Technology InternationalRequires access

Determination of trace heavy metal elements in fish oil using ICP-MS

Liang Fu

Open publisher page 0 citations

Abstract

An octopole reaction system(ORS) inductively coupled plasma mass spectrometry(ICP-MS) was developed for the determination of Cr, Co, Ni, As, Mo, Cd, Sn, Sb, Hg and Pb in fish oil. Samples were decomposed by HNO 3 and H2 O2 followed by dilution with ultrapure water then the above 10 heavy metal elements in the solution were analyzed directly by ICP-MS. The use of ORS can eliminate the interference of polyatomic ions dramatically. Sc, Rh and Bi were used to correct the matrix interference and drift. The detection limits of the 10 elements was in the range of 0.008~0.073 μg/L, the relative standard deviation was less than 4.4% for all the elements, and the recovery was 89.6%~103.8% by adding standard recovery experiment. This method was rapid, simple and applicable for the analysis of trace heavy metal elements in fish oil.

About this research paper

What this paper is about

An octopole reaction system(ORS) inductively coupled plasma mass spectrometry(ICP-MS) was developed for the determination of Cr, Co, Ni, As, Mo, Cd, Sn, Sb, Hg and Pb in fish oil. Samples were decomposed by HNO 3 and H2 O2 followed by dilution with ultrapure water then the above 10 heavy metal elements in the solution were analyzed directly by ICP-MS. The use of ORS can eliminate the interference of polyatomic ions dramatically. Sc, Rh and Bi were used to correct the matrix interference and drift. The detection limits of the 10 elements was in the range of 0.008~0.073 μg/L, the relative standard deviation was less than 4.4% for all the elements, and the recovery was 89.6%~103.8% by adding standard recovery experiment. This method was rapid, simple and applicable for the analysis of trace heavy metal elements in fish oil.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An octopole reaction system(ORS) inductively coupled plasma mass spectrometry(ICP-MS) was developed for the determination of Cr, Co, Ni, As, Mo, Cd, Sn, Sb, Hg and Pb in fish oil. Samples were decomposed by HNO 3 and H2 O2 followed by dilution with ultrapure water then the above 10 heavy metal elements in the solution were analyzed directly by ICP-MS. The use of ORS can eliminate the interference of polyatomic ions dramatically. Sc, Rh and Bi were used to correct the matrix interference and drift. The detection limits of the 10 elements was in the range of 0.008~0.073 μg/L, the relative standard deviation was less than 4.4% for all the elements, and the recovery was 89.6%~103.8% by adding standard recovery experiment. This method was rapid, simple and applicable for the analysis of trace heavy metal elements in fish oil.

Key concepts: Ultrapure water, Inductively coupled plasma mass spectrometry, Chemistry, Polyatomic ion, Dilution, Analytical Chemistry (journal), Metal, Metal ions in aqueous solution

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of trace heavy metal elements in fish oil using ICP-MS — Research Paper | ScholarLens