2010Journal of Instrumental AnalysisRequires access

Determination of Rutaecarpine and Evodiamine in Evodia Rutaecarpa by Supercritical Fluid Chromatography

Guo Ya-dong

Open publisher page 0 citations

Abstract

A supercritical fluid chromatographic(SFC) method for the determination of rutaecarpine and evodiamine in Evodia rutaecarpa was established.The separation of rutaecarpine and evodiamine was performed on a Kromasil Slica column(250 mm×4.6 mm,5 μm) using CO2 containing 13% methanol as mobile phase at a flow rate of 2.0 mL·min-1.The back pressure was set at 2.0×107 Pa and the column temperature was 60 ℃.The detection wavelength was 225 nm.The result indicated that the linear ranges of rutaecarpine and evodiamine were in the range of 0.33-8.25 μg(r=0.999 3) and 0.68-17 μg(r= 0.999 8),respectively.The average recoveries were both 100% with RSD of 2.6% for rutaecarpine and 3.1% for evodiamine,respectively.Comparing with the traditional method,the proposed method was simple,rapid and sensitive,and could be successfully applied in the separation of rutaecarpine and evodiamine.

About this research paper

What this paper is about

A supercritical fluid chromatographic(SFC) method for the determination of rutaecarpine and evodiamine in Evodia rutaecarpa was established.The separation of rutaecarpine and evodiamine was performed on a Kromasil Slica column(250 mm×4.6 mm,5 μm) using CO2 containing 13% methanol as mobile phase at a flow rate of 2.0 mL·min-1.The back pressure was set at 2.0×107 Pa and the column temperature was 60 ℃.The detection wavelength was 225 nm.The result indicated that the linear ranges of rutaecarpine and evodiamine were in the range of 0.33-8.25 μg(r=0.999 3) and 0.68-17 μg(r= 0.999 8),respectively.The average recoveries were both 100% with RSD of 2.6% for rutaecarpine and 3.1% for evodiamine,respectively.Comparing with the traditional method,the proposed method was simple,rapid and sensitive,and could be successfully applied in the separation of rutaecarpine and evodiamine.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A supercritical fluid chromatographic(SFC) method for the determination of rutaecarpine and evodiamine in Evodia rutaecarpa was established.The separation of rutaecarpine and evodiamine was performed on a Kromasil Slica column(250 mm×4.6 mm,5 μm) using CO2 containing 13% methanol as mobile phase at a flow rate of 2.0 mL·min-1.The back pressure was set at 2.0×107 Pa and the column temperature was 60 ℃.The detection wavelength was 225 nm.The result indicated that the linear ranges of rutaecarpine and evodiamine were in the range of 0.33-8.25 μg(r=0.999 3) and 0.68-17 μg(r= 0.999 8),respectively.The average recoveries were both 100% with RSD of 2.6% for rutaecarpine and 3.1% for evodiamine,respectively.Comparing with the traditional method,the proposed method was simple,rapid and sensitive,and could be successfully applied in the separation of rutaecarpine and evodiamine.

Key concepts: Evodiamine, Rutaecarpine, Chemistry, Chromatography, Supercritical fluid, Supercritical fluid chromatography, High-performance liquid chromatography, Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Rutaecarpine and Evodiamine in Evodia Rutaecarpa by Supercritical Fluid Chromatography — Research Paper | ScholarLens