[Simultaneous determination of 31 volatile organic compounds in decorated rooms by two-stage thermal desorption-capillary gas chromatography].
Xiaoyan Dong, Junrui Chang, Yunpu Li, Qin Lin Wang, Guifang Wang, Zhigang Tang, Dongqun Xun
Abstract
Xiaoyan Dong, Junrui Chang, Yunpu Li, Qin Lin Wang, Guifang Wang, Zhigang Tang, Dongqun Xun
Abstract
OBJECTIVE: To establish the monitoring method to simultaneously measure 31 volatile organic compounds in decorated rooms using two-stage thermal desorption-capillary gas chromatography. METHODS: Using the Tenax TA absorption tube to sample, and subsequently desorbed and analyzed by two-stage thermal desorption capillary gas chromatography column, and measured by FID detector. RESULTS: 31 volatile organic compounds can be well separated in the chromatography column. In the experiment, the relative standard deviations of the reoccuring of each compound were within 10%. All the correlation coefficients of linear regression equation were greater than 0.99. The lowest detection limit can reach the concentration level of 1 ng/microl, and the recoveries were 83.2% - 106%. CONCLUSION: The method is applicable to determination of 31 volatile organic compounds in the decorated rooms simultaneously.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To establish the monitoring method to simultaneously measure 31 volatile organic compounds in decorated rooms using two-stage thermal desorption-capillary gas chromatography. METHODS: Using the Tenax TA absorption tube to sample, and subsequently desorbed and analyzed by two-stage thermal desorption capillary gas chromatography column, and measured by FID detector. RESULTS: 31 volatile organic compounds can be well separated in the chromatography column. In the experiment, the relative standard deviations of the reoccuring of each compound were within 10%. All the correlation coefficients of linear regression equation were greater than 0.99. The lowest detection limit can reach the concentration level of 1 ng/microl, and the recoveries were 83.2% - 106%. CONCLUSION: The method is applicable to determination of 31 volatile organic compounds in the decorated rooms simultaneously.
Key concepts: Tenax, Thermal desorption, Chromatography, Gas chromatography, Chemistry, Detection limit, Capillary action, Desorption