Determination of total volatile organic compounds by thermal desorption-gas chromatography in indoor air
Jun Tang
Abstract
Jun Tang
Abstract
Objective:To the code for indoor environmental pollution control of civil building engineering-GB50325-2001.A method have developed for determination of the total volatile organic compounds in indoor air by thermal desorption/gas chromatography-hydrogen flame ionixation detector.Methods:The total volatile organic compounds in indoor air or mixed standard solutions were adsorbed by Tenax-TA thermal desorption tubes,then desorbed by thermal desortpion and detected by gas chromatography.Results:The experimental results indicated that the linear range were wide,the precise were high,The detection limits were 0.2 ng~0.3 ng,and the relative standard deviations(RSD) were 0.31%~2.6%,the minimum detection concentration were 0.0002 mg/m3~0.0003 mg/m3(the air volume=5.0 L).Conclusion:It is a quick,accurate,sensentive method to detect the total volatile organic compounds in indoor air by thermal desorption/gas chromatography-hydrogen flame ionixation detector.Even most of the unknown compounds in indoor air can be recongnized by 54 volatile organic compounds.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To the code for indoor environmental pollution control of civil building engineering-GB50325-2001.A method have developed for determination of the total volatile organic compounds in indoor air by thermal desorption/gas chromatography-hydrogen flame ionixation detector.Methods:The total volatile organic compounds in indoor air or mixed standard solutions were adsorbed by Tenax-TA thermal desorption tubes,then desorbed by thermal desortpion and detected by gas chromatography.Results:The experimental results indicated that the linear range were wide,the precise were high,The detection limits were 0.2 ng~0.3 ng,and the relative standard deviations(RSD) were 0.31%~2.6%,the minimum detection concentration were 0.0002 mg/m3~0.0003 mg/m3(the air volume=5.0 L).Conclusion:It is a quick,accurate,sensentive method to detect the total volatile organic compounds in indoor air by thermal desorption/gas chromatography-hydrogen flame ionixation detector.Even most of the unknown compounds in indoor air can be recongnized by 54 volatile organic compounds.
Key concepts: Thermal desorption, Gas chromatography, Tenax, Chemistry, Detection limit, Desorption, Volatile organic compound, Chromatography