2002Unpublished venueRequires access

MEASUREMENT OF SERUM INSULIN BY ELECTROCHEMILUMINESCENT IMMUNOASSAY

QI Yuqin

Open publisher page 0 citations

Abstract

Objective To evaluate the effectiveness and clinical value of the detection of serum insulin by elctrochemiluminescent immunoassay(ECLIA). Methods Serum insulin of diabetic patients was detected by ECLIA and radioimmunoassay(RIA). C peptide was measured by ELISA simultaneously. Results The coefficient of variations(CVs) of within run and between run of ECLIA was 1.97% and 2.56% respectively,while that of RIA was 10.18% and 13.21%.The average rate of recovery of ECLIA was 99.5% and RIA was 93.4%.The concentration of serum insulin measured by both ECLIA and RIA was positively correlated with c peptide ( r=0.94 , 0.91, P 0.01). Conclusion All the technical parameters of ECLIA in measuring serum insulin gain an advantage over those of RIA. It can be used to judge B cell function of pancreas. This method is valuable for clinical application as it is easy and quick to do.

About this research paper

What this paper is about

Objective To evaluate the effectiveness and clinical value of the detection of serum insulin by elctrochemiluminescent immunoassay(ECLIA). Methods Serum insulin of diabetic patients was detected by ECLIA and radioimmunoassay(RIA). C peptide was measured by ELISA simultaneously. Results The coefficient of variations(CVs) of within run and between run of ECLIA was 1.97% and 2.56% respectively,while that of RIA was 10.18% and 13.21%.The average rate of recovery of ECLIA was 99.5% and RIA was 93.4%.The concentration of serum insulin measured by both ECLIA and RIA was positively correlated with c peptide ( r=0.94 , 0.91, P 0.01). Conclusion All the technical parameters of ECLIA in measuring serum insulin gain an advantage over those of RIA. It can be used to judge B cell function of pancreas. This method is valuable for clinical application as it is easy and quick to do.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the effectiveness and clinical value of the detection of serum insulin by elctrochemiluminescent immunoassay(ECLIA). Methods Serum insulin of diabetic patients was detected by ECLIA and radioimmunoassay(RIA). C peptide was measured by ELISA simultaneously. Results The coefficient of variations(CVs) of within run and between run of ECLIA was 1.97% and 2.56% respectively,while that of RIA was 10.18% and 13.21%.The average rate of recovery of ECLIA was 99.5% and RIA was 93.4%.The concentration of serum insulin measured by both ECLIA and RIA was positively correlated with c peptide ( r=0.94 , 0.91, P 0.01). Conclusion All the technical parameters of ECLIA in measuring serum insulin gain an advantage over those of RIA. It can be used to judge B cell function of pancreas. This method is valuable for clinical application as it is easy and quick to do.

Key concepts: Radioimmunoassay, Immunoassay, Insulin, Internal medicine, Endocrinology, Medicine, Chemistry, Immunology

Related papers

Back to paper searchBrowse research topicsOriginal source
MEASUREMENT OF SERUM INSULIN BY ELECTROCHEMILUMINESCENT IMMUNOASSAY — Research Paper | ScholarLens