2010Chinese Journal of Analysis LaboratoryRequires access

Study on the determination of 16 pesticides residues in water environment by solid-phase extraction-high performance liquid chromatography

Yanqing Ye

Open publisher page 0 citations

Abstract

A method for the determination of 16 pesticide residues in water by solid-phase extraction-high performance liquid chromatography with an UV detector was established. The pesticides were enriched by C18 solid-phase extraction cartridges,eluted by methanol and quantified by external standard method. Linearity was obtained in the range from 0.25 to 10 mg/L with correlation coefficients from 0.9990 to 0.9999. The average spiked recoveries ranged from 70.7% to 112.2%,and the relative standard deviations ranged from 1.6% to 12%. Detection limits of this method were from 0.01 mg/L to 0.23 mg/L.

About this research paper

What this paper is about

A method for the determination of 16 pesticide residues in water by solid-phase extraction-high performance liquid chromatography with an UV detector was established. The pesticides were enriched by C18 solid-phase extraction cartridges,eluted by methanol and quantified by external standard method. Linearity was obtained in the range from 0.25 to 10 mg/L with correlation coefficients from 0.9990 to 0.9999. The average spiked recoveries ranged from 70.7% to 112.2%,and the relative standard deviations ranged from 1.6% to 12%. Detection limits of this method were from 0.01 mg/L to 0.23 mg/L.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for the determination of 16 pesticide residues in water by solid-phase extraction-high performance liquid chromatography with an UV detector was established. The pesticides were enriched by C18 solid-phase extraction cartridges,eluted by methanol and quantified by external standard method. Linearity was obtained in the range from 0.25 to 10 mg/L with correlation coefficients from 0.9990 to 0.9999. The average spiked recoveries ranged from 70.7% to 112.2%,and the relative standard deviations ranged from 1.6% to 12%. Detection limits of this method were from 0.01 mg/L to 0.23 mg/L.

Key concepts: Chemistry, Chromatography, Solid phase extraction, Elution, Cartridge, Extraction (chemistry), Detection limit, Pesticide

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the determination of 16 pesticides residues in water environment by solid-phase extraction-high performance liquid chromatography — Research Paper | ScholarLens