2013Zhongguo xiandai yixue/Zhongguo xiandai yixue zazhiRequires access

The clinical reportable range of D-dimer on the automatic hemagglutinin apparatus Sysmex Ca1500

Jingjian Wang

Open publisher page 0 citations

Abstract

【Objective】To establish the clinical reportable range of D-dimer by immunoturbidimetry method.【Methods】The analytical measurement range(AMR) and the maximum allowable dilution rate were validated on Automatic Sysmex Ca1500,according to NCCLS EP6-P2 evaluation protocols and relevant literature.Combined with functional sensitivity,the clinical reportable range was established.【Results】 The AMR of D-dimer was during 29~1 980 ng/mL,and the maximum allowable dilution was 1 ∶ 8,which was consistent with the manufacturer's data.The clinical reportable range was 54.7~15 840 ng/mL.【Conclusions】 The clinical reportable range was established,which was significant for clinical diagnosis with the high test value.

About this research paper

What this paper is about

【Objective】To establish the clinical reportable range of D-dimer by immunoturbidimetry method.【Methods】The analytical measurement range(AMR) and the maximum allowable dilution rate were validated on Automatic Sysmex Ca1500,according to NCCLS EP6-P2 evaluation protocols and relevant literature.Combined with functional sensitivity,the clinical reportable range was established.【Results】 The AMR of D-dimer was during 29~1 980 ng/mL,and the maximum allowable dilution was 1 ∶ 8,which was consistent with the manufacturer's data.The clinical reportable range was 54.7~15 840 ng/mL.【Conclusions】 The clinical reportable range was established,which was significant for clinical diagnosis with the high test value.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

【Objective】To establish the clinical reportable range of D-dimer by immunoturbidimetry method.【Methods】The analytical measurement range(AMR) and the maximum allowable dilution rate were validated on Automatic Sysmex Ca1500,according to NCCLS EP6-P2 evaluation protocols and relevant literature.Combined with functional sensitivity,the clinical reportable range was established.【Results】 The AMR of D-dimer was during 29~1 980 ng/mL,and the maximum allowable dilution was 1 ∶ 8,which was consistent with the manufacturer's data.The clinical reportable range was 54.7~15 840 ng/mL.【Conclusions】 The clinical reportable range was established,which was significant for clinical diagnosis with the high test value.

Key concepts: Medicine, D-dimer, Clinical diagnosis, Internal medicine, Intensive care medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
The clinical reportable range of D-dimer on the automatic hemagglutinin apparatus Sysmex Ca1500 — Research Paper | ScholarLens