2008•China Medical HeraldRequires access

Content determination of Atropine Sulfate Eye Drops by HPLC

Fan Yi-feng

Open publisher page 0 citations

Abstract

Objective: To determine the content of atropine sulfate in Atropine Sulfate Eye Drops by HPLC. Methods: SPHERIGEL C18 (150 mm×4.6 mm,5 μm) was used as column with the detective wavelength of 217 nm,the mobile phase was methanol-0.5%KH2PO4 (35∶65) ,and the flow rate was 1.0 ml/min. Results: Caliation curve was linear over the rang of 40.0~160.0 μg/ml ,the regression quation was H=0.916 4C-4.840 (r=0.999 9), for potency assay the mean recovery was 100.3%,RSD was 0.93%. Conclusion: The proposed method is simple, selective and accurate. It can be used for quality control of Atropine Sulfate Eye Drops.

About this research paper

What this paper is about

Objective: To determine the content of atropine sulfate in Atropine Sulfate Eye Drops by HPLC. Methods: SPHERIGEL C18 (150 mm×4.6 mm,5 μm) was used as column with the detective wavelength of 217 nm,the mobile phase was methanol-0.5%KH2PO4 (35∶65) ,and the flow rate was 1.0 ml/min. Results: Caliation curve was linear over the rang of 40.0~160.0 μg/ml ,the regression quation was H=0.916 4C-4.840 (r=0.999 9), for potency assay the mean recovery was 100.3%,RSD was 0.93%. Conclusion: The proposed method is simple, selective and accurate. It can be used for quality control of Atropine Sulfate Eye Drops.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To determine the content of atropine sulfate in Atropine Sulfate Eye Drops by HPLC. Methods: SPHERIGEL C18 (150 mm×4.6 mm,5 μm) was used as column with the detective wavelength of 217 nm,the mobile phase was methanol-0.5%KH2PO4 (35∶65) ,and the flow rate was 1.0 ml/min. Results: Caliation curve was linear over the rang of 40.0~160.0 μg/ml ,the regression quation was H=0.916 4C-4.840 (r=0.999 9), for potency assay the mean recovery was 100.3%,RSD was 0.93%. Conclusion: The proposed method is simple, selective and accurate. It can be used for quality control of Atropine Sulfate Eye Drops.

Key concepts: Atropine sulfate, Atropine, Medicine, Chromatography, High-performance liquid chromatography, Content determination, Anesthesia, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Content determination of Atropine Sulfate Eye Drops by HPLC — Research Paper | ScholarLens