2008PubMedRequires access

[Effect of humic acids on determining polyhydroxy phenol by flow-injection chemiluminescence].

Bao-Jun Ding, Fenglin Yang, Zhenliang Zhu, Guang Xiao, Li-Jun Cui

Open publisher page 1 citations

Abstract

Flow-injection chemiluminescence was applied to determine the trace polyhydroxy phenol in environment (soil and water). Based on the comparison of several different chemiluminescence systems and optimization, an alkaline luminol-NaIO4 system for determinating polyhydroxy phenol was chosen. During the process of polyhydroxy phenol determination, the effect of dissolved humic acid (HA) on the determination of phenol by this chemiluminescence system was also considered, which generally coexists in soil and water widely. Thus the present work provided the reference for the determination of the real samples coming from soil or water. An obvious restraining effect of humic acid on the chemiluminescence signal obtained by the luminol-NaIO4-polyhydroxy phenol system was found, which shows a linear relationship with the concentration of HA in a certain range, the linear equation is y = 70.36x + 540.1, the correlation coefficient is 0. 9954, the linear range is between 3-15 mg x L(-1), the limitation of detection is 0.749 mg x L(-1), and the relative standard deviation (RSD) is 1.08% when the concentration of HA is 6 mg x L(-1). The possible working mechanism of humic acid here is discussed and deduced.

About this research paper

What this paper is about

Flow-injection chemiluminescence was applied to determine the trace polyhydroxy phenol in environment (soil and water). Based on the comparison of several different chemiluminescence systems and optimization, an alkaline luminol-NaIO4 system for determinating polyhydroxy phenol was chosen. During the process of polyhydroxy phenol determination, the effect of dissolved humic acid (HA) on the determination of phenol by this chemiluminescence system was also considered, which generally coexists in soil and water widely. Thus the present work provided the reference for the determination of the real samples coming from soil or water. An obvious restraining effect of humic acid on the chemiluminescence signal obtained by the luminol-NaIO4-polyhydroxy phenol system was found, which shows a linear relationship with the concentration of HA in a certain range, the linear equation is y = 70.36x + 540.1, the correlation coefficient is 0. 9954, the linear range is between 3-15 mg x L(-1), the limitation of detection is 0.749 mg x L(-1), and the relative standard deviation (RSD) is 1.08% when the concentration of HA is 6 mg x L(-1). The possible working mechanism of humic acid here is discussed and deduced.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Flow-injection chemiluminescence was applied to determine the trace polyhydroxy phenol in environment (soil and water). Based on the comparison of several different chemiluminescence systems and optimization, an alkaline luminol-NaIO4 system for determinating polyhydroxy phenol was chosen. During the process of polyhydroxy phenol determination, the effect of dissolved humic acid (HA) on the determination of phenol by this chemiluminescence system was also considered, which generally coexists in soil and water widely. Thus the present work provided the reference for the determination of the real samples coming from soil or water. An obvious restraining effect of humic acid on the chemiluminescence signal obtained by the luminol-NaIO4-polyhydroxy phenol system was found, which shows a linear relationship with the concentration of HA in a certain range, the linear equation is y = 70.36x + 540.1, the correlation coefficient is 0. 9954, the linear range is between 3-15 mg x L(-1), the limitation of detection is 0.749 mg x L(-1), and the relative standard deviation (RSD) is 1.08% when the concentration of HA is 6 mg x L(-1). The possible working mechanism of humic acid here is discussed and deduced.

Key concepts: Chemiluminescence, Luminol, Phenol, Chemistry, Humic acid, Flow injection analysis, Detection limit, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
[Effect of humic acids on determining polyhydroxy phenol by flow-injection chemiluminescence]. — Research Paper | ScholarLens