2005PubMedRequires access

[Flow injection chemiluminescence method for the determination of phenol with N-bromosuccinimide-luminol system].

Du L, Ning‐Ning Ji, Shuhao Wang, Huisheng Zhuang

Open publisher page 1 citations

Abstract

A novel flow injection chemiluminescence method was presented for the determination of phenol. The method is based on the quenching effect of phenols on the chemiluminescence reaction between luminol and N-bromosuccinimide. The linear range for the determination of phenol is 1.0 x 10(-5) -9.0 x 10(-4) mg x mL(-1), and the detection limit is 1.81 x 10(-7) mg x mL(-1). This method was used for the determination of phenol in water samples with satisfactory results. The mechanism of the reaction was also expounded.

About this research paper

What this paper is about

A novel flow injection chemiluminescence method was presented for the determination of phenol. The method is based on the quenching effect of phenols on the chemiluminescence reaction between luminol and N-bromosuccinimide. The linear range for the determination of phenol is 1.0 x 10(-5) -9.0 x 10(-4) mg x mL(-1), and the detection limit is 1.81 x 10(-7) mg x mL(-1). This method was used for the determination of phenol in water samples with satisfactory results. The mechanism of the reaction was also expounded.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A novel flow injection chemiluminescence method was presented for the determination of phenol. The method is based on the quenching effect of phenols on the chemiluminescence reaction between luminol and N-bromosuccinimide. The linear range for the determination of phenol is 1.0 x 10(-5) -9.0 x 10(-4) mg x mL(-1), and the detection limit is 1.81 x 10(-7) mg x mL(-1). This method was used for the determination of phenol in water samples with satisfactory results. The mechanism of the reaction was also expounded.

Key concepts: Chemiluminescence, Luminol, Phenol, Detection limit, Chemistry, N-Bromosuccinimide, Flow injection analysis, Phenols

Related papers

Back to paper searchBrowse research topicsOriginal source
[Flow injection chemiluminescence method for the determination of phenol with N-bromosuccinimide-luminol system]. — Research Paper | ScholarLens