2010Chemical Research and ApplicationRequires access

Determination of phenol by flow injection inhibitory chemiluminescence method

Shuhao Wang

Open publisher page 1 citations

Abstract

A new flow injection chemiluminesenet method was presented for the determination of phenol based on the inhibition effect of trace phenol on the chemiluminescence reaction between luminol and N-chlorosuccinimide system.The linear range for the determination of phenol is 1.5×10-5~3.5×10-4mg/mL,the detection limit is 2.36×10-6mg/mL.This method has been used for the determination of phenol in water samples with satisfactory results.The mechanism of the inhibitory reaction was also discussed.

About this research paper

What this paper is about

A new flow injection chemiluminesenet method was presented for the determination of phenol based on the inhibition effect of trace phenol on the chemiluminescence reaction between luminol and N-chlorosuccinimide system.The linear range for the determination of phenol is 1.5×10-5~3.5×10-4mg/mL,the detection limit is 2.36×10-6mg/mL.This method has been used for the determination of phenol in water samples with satisfactory results.The mechanism of the inhibitory reaction was also discussed.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new flow injection chemiluminesenet method was presented for the determination of phenol based on the inhibition effect of trace phenol on the chemiluminescence reaction between luminol and N-chlorosuccinimide system.The linear range for the determination of phenol is 1.5×10-5~3.5×10-4mg/mL,the detection limit is 2.36×10-6mg/mL.This method has been used for the determination of phenol in water samples with satisfactory results.The mechanism of the inhibitory reaction was also discussed.

Key concepts: Chemiluminescence, Phenol, Chemistry, Detection limit, Luminol, Linear range, Chromatography, Phenols

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of phenol by flow injection inhibitory chemiluminescence method — Research Paper | ScholarLens