2006Journal of environmental healthRequires access

Indoor Air Pollution by Formaldehyde in Shandong University

Gao Can-zh

Open publisher page 0 citations

Abstract

Objective To know the situation of formaldehyde pollution in the indoor air and the influencing factors in Shandong University. Methods PPM400 formaldehyde analyzer adjusted with spectrophotometry was used to determine the concentration of formaldehyde in the indoor air in the rooms which were decorated in different levels in the campus of Shandong University. Results The average concentration of formaldehyde in the indoor air was 0.05 mg/m3(median), in the outdoor air it was below the detection limit. The qualified rate of formaldehyde concentration in indoor air was 79.6%. The average concentration of formaldehyde in indoor air was(0.045±0.003 )mg/m3 with the windows open and it was (0.212±0.079)mg/m3 with the windows closed. Conclusion The indoor air of Shandong University is polluted with formaldehyde to some extent. Fitment and use of veneers, flakeboard are the main pollutant source. The level of formaldehyde pollution is higher in the newly or nicely decorated rooms and in bad ventilation.

About this research paper

What this paper is about

Objective To know the situation of formaldehyde pollution in the indoor air and the influencing factors in Shandong University. Methods PPM400 formaldehyde analyzer adjusted with spectrophotometry was used to determine the concentration of formaldehyde in the indoor air in the rooms which were decorated in different levels in the campus of Shandong University. Results The average concentration of formaldehyde in the indoor air was 0.05 mg/m3(median), in the outdoor air it was below the detection limit. The qualified rate of formaldehyde concentration in indoor air was 79.6%. The average concentration of formaldehyde in indoor air was(0.045±0.003 )mg/m3 with the windows open and it was (0.212±0.079)mg/m3 with the windows closed. Conclusion The indoor air of Shandong University is polluted with formaldehyde to some extent. Fitment and use of veneers, flakeboard are the main pollutant source. The level of formaldehyde pollution is higher in the newly or nicely decorated rooms and in bad ventilation.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To know the situation of formaldehyde pollution in the indoor air and the influencing factors in Shandong University. Methods PPM400 formaldehyde analyzer adjusted with spectrophotometry was used to determine the concentration of formaldehyde in the indoor air in the rooms which were decorated in different levels in the campus of Shandong University. Results The average concentration of formaldehyde in the indoor air was 0.05 mg/m3(median), in the outdoor air it was below the detection limit. The qualified rate of formaldehyde concentration in indoor air was 79.6%. The average concentration of formaldehyde in indoor air was(0.045±0.003 )mg/m3 with the windows open and it was (0.212±0.079)mg/m3 with the windows closed. Conclusion The indoor air of Shandong University is polluted with formaldehyde to some extent. Fitment and use of veneers, flakeboard are the main pollutant source. The level of formaldehyde pollution is higher in the newly or nicely decorated rooms and in bad ventilation.

Key concepts: Formaldehyde, Indoor air, Environmental science, Indoor air quality, Pollutant, Air pollution, Ventilation (architecture), Pollution

Related papers

Back to paper searchBrowse research topicsOriginal source