2010Physical Testing and Chemical AnalysisRequires access

AFS Determination of Total Arsenic in Sugar with Microwave Assisted Sample Digestion

Tang Zhao-ling

Open publisher page 0 citations

Abstract

The sugar sample was digested with HNO3 and H2O2 in the MWS-2 microwave sample digestion system under pressure.The solution obtained was then evaporated to expel excess nitric acid.Mixed solution of thiourea and ascorbic acid was added as pre-reductant and complexing agent and the solution,after diluting to 50 mL,was used for AFS determination of arsenic under the optimum working condition of the instrument.Linear relationship between values of peak area and mass concentration of arsenic was obtained in the range within 10.0 μg·L-1,and the detection limit(3s/k) found was 0.045 μg·L-1.Two sugar samples were analyzed by this method,and recovery was tested by standard addition method using these 2 samples as matrixes,giving values of average recovery of 96.7% and 100.0%.

About this research paper

What this paper is about

The sugar sample was digested with HNO3 and H2O2 in the MWS-2 microwave sample digestion system under pressure.The solution obtained was then evaporated to expel excess nitric acid.Mixed solution of thiourea and ascorbic acid was added as pre-reductant and complexing agent and the solution,after diluting to 50 mL,was used for AFS determination of arsenic under the optimum working condition of the instrument.Linear relationship between values of peak area and mass concentration of arsenic was obtained in the range within 10.0 μg·L-1,and the detection limit(3s/k) found was 0.045 μg·L-1.Two sugar samples were analyzed by this method,and recovery was tested by standard addition method using these 2 samples as matrixes,giving values of average recovery of 96.7% and 100.0%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The sugar sample was digested with HNO3 and H2O2 in the MWS-2 microwave sample digestion system under pressure.The solution obtained was then evaporated to expel excess nitric acid.Mixed solution of thiourea and ascorbic acid was added as pre-reductant and complexing agent and the solution,after diluting to 50 mL,was used for AFS determination of arsenic under the optimum working condition of the instrument.Linear relationship between values of peak area and mass concentration of arsenic was obtained in the range within 10.0 μg·L-1,and the detection limit(3s/k) found was 0.045 μg·L-1.Two sugar samples were analyzed by this method,and recovery was tested by standard addition method using these 2 samples as matrixes,giving values of average recovery of 96.7% and 100.0%.

Key concepts: Arsenic, Chemistry, Thiourea, Nitric acid, Ascorbic acid, Detection limit, Microwave digestion, Sugar

Related papers

Back to paper searchBrowse research topicsOriginal source
AFS Determination of Total Arsenic in Sugar with Microwave Assisted Sample Digestion — Research Paper | ScholarLens