2001•Journalof Southwest China Normal UniversityRequires access

Determination of Apomorphini by Resver Phase HPLC

Zhao Mu

Open publisher page 0 citations

Abstract

A simple,rapid,accurate and reliable resver phase HPLC method was established for the determination apomorphini in its tablets Apomorphini can be separated on Kromasil C 18 (4 6 mm×250 mm,5 μm) column by using methabnol—0 02 mol/LKH 2PO 4(67∶33)(pH=4 60)as mobile phase with UV detector at a wavelength of 272nm The standard curve was linear in the concentration range 10~60 μg/ml and the correlation coefficient was 0 999 7 The average recovery and RSD was 98 56% and 1 44% respectively The detection limit was 4 ng

About this research paper

What this paper is about

A simple,rapid,accurate and reliable resver phase HPLC method was established for the determination apomorphini in its tablets Apomorphini can be separated on Kromasil C 18 (4 6 mm×250 mm,5 μm) column by using methabnol—0 02 mol/LKH 2PO 4(67∶33)(pH=4 60)as mobile phase with UV detector at a wavelength of 272nm The standard curve was linear in the concentration range 10~60 μg/ml and the correlation coefficient was 0 999 7 The average recovery and RSD was 98 56% and 1 44% respectively The detection limit was 4 ng

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple,rapid,accurate and reliable resver phase HPLC method was established for the determination apomorphini in its tablets Apomorphini can be separated on Kromasil C 18 (4 6 mm×250 mm,5 μm) column by using methabnol—0 02 mol/LKH 2PO 4(67∶33)(pH=4 60)as mobile phase with UV detector at a wavelength of 272nm The standard curve was linear in the concentration range 10~60 μg/ml and the correlation coefficient was 0 999 7 The average recovery and RSD was 98 56% and 1 44% respectively The detection limit was 4 ng

Key concepts: Chromatography, High-performance liquid chromatography, Correlation coefficient, Detection limit, Standard curve, Linear correlation, Linear range, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Apomorphini by Resver Phase HPLC — Research Paper | ScholarLens