2014•Journal of Applied OpticsRequires access

Calibration method of VNIR solar irradiance spectroradiometer

Zhang Yan-n

Open publisher page 1 citations

Abstract

To meet the requirements of visible-near infrared(VNIR)high-precision observation of solar spectrum,a calibration method for a novel solar irradiance spectroradiometer based on spectrally-resolving technology was developed.The relative calibration based on standard lamp was carried out in 400nm ~1 050nm,and the Langley method was carried out in the band satisfying Beer-Lambert theorem,where after the solar irradiance spectroradiometer was traced to the solar spectral irradiance on the top of atmosphere(TOA)in the whole bands.The experiments carried out in Dunhuang and Hefei showed,the observation results were consistent with the MODTRAN4.0theoretical model,and the deviations with CE318were less than 5%in the four aerosol observation bands,which validated the rationality of the calibration method.

About this research paper

What this paper is about

To meet the requirements of visible-near infrared(VNIR)high-precision observation of solar spectrum,a calibration method for a novel solar irradiance spectroradiometer based on spectrally-resolving technology was developed.The relative calibration based on standard lamp was carried out in 400nm ~1 050nm,and the Langley method was carried out in the band satisfying Beer-Lambert theorem,where after the solar irradiance spectroradiometer was traced to the solar spectral irradiance on the top of atmosphere(TOA)in the whole bands.The experiments carried out in Dunhuang and Hefei showed,the observation results were consistent with the MODTRAN4.0theoretical model,and the deviations with CE318were less than 5%in the four aerosol observation bands,which validated the rationality of the calibration method.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To meet the requirements of visible-near infrared(VNIR)high-precision observation of solar spectrum,a calibration method for a novel solar irradiance spectroradiometer based on spectrally-resolving technology was developed.The relative calibration based on standard lamp was carried out in 400nm ~1 050nm,and the Langley method was carried out in the band satisfying Beer-Lambert theorem,where after the solar irradiance spectroradiometer was traced to the solar spectral irradiance on the top of atmosphere(TOA)in the whole bands.The experiments carried out in Dunhuang and Hefei showed,the observation results were consistent with the MODTRAN4.0theoretical model,and the deviations with CE318were less than 5%in the four aerosol observation bands,which validated the rationality of the calibration method.

Key concepts: VNIR, Spectroradiometer, Irradiance, Remote sensing, Solar irradiance, Calibration, Moderate-resolution imaging spectroradiometer, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Calibration method of VNIR solar irradiance spectroradiometer — Research Paper | ScholarLens