2001•Applied OpticsRequires access

Direct solar spectral irradiance and transmittance measurements from 350 to 2500 nm

B. C. Kindel, Zheng Qu, Alexander F. H. Goetz

Open publisher page 51 citations

Abstract

A radiometrically stable, commercially available spectroradiometer was used in conjunction with a simple, custom-designed telescope to make spectrally continuous measurements of solar spectral transmittance and directly transmitted solar spectral irradiance. The wavelength range of the instrument is 350-2500 nm and the resolution is 3-11.7 nm. Laboratory radiometric calibrations show the instrument to be stable to better than 1.0% over a nine-month period. The instrument and telescope are highly portable, can be set up in a matter of minutes, and can be operated by one person. A method of absolute radiometric calibration that can be tied to published top-of-the-atmosphere (TOA) solar spectra in valid Langley channels as well as regions of strong molecular absorption is also presented. High-altitude Langley plot calibration experiments indicate that this technique is limited ultimately by the current uncertainties in the TOA solar spectra, approximately 2-3%. Example comparisons of measured and modtran-modeled direct solar irradiance show that the model can be parameterized to agree with measurements over the large majority of the wavelength range to the 3% level for the two example cases shown. Side-by-side comparisons with a filter-based solar radiometer are in excellent agreement, with a mean absolute difference of tau = 0.0036 for eight overlapping wavelengths over three experiment days.

About this research paper

What this paper is about

A radiometrically stable, commercially available spectroradiometer was used in conjunction with a simple, custom-designed telescope to make spectrally continuous measurements of solar spectral transmittance and directly transmitted solar spectral irradiance. The wavelength range of the instrument is 350-2500 nm and the resolution is 3-11.7 nm. Laboratory radiometric calibrations show the instrument to be stable to better than 1.0% over a nine-month period. The instrument and telescope are highly portable, can be set up in a matter of minutes, and can be operated by one person. A method of absolute radiometric calibration that can be tied to published top-of-the-atmosphere (TOA) solar spectra in valid Langley channels as well as regions of strong molecular absorption is also presented. High-altitude Langley plot calibration experiments indicate that this technique is limited ultimately by the current uncertainties in the TOA solar spectra, approximately 2-3%. Example comparisons of measured and modtran-modeled direct solar irradiance show that the model can be parameterized to agree with measurements over the large majority of the wavelength range to the 3% level for the two example cases shown. Side-by-side comparisons with a filter-based solar radiometer are in excellent agreement, with a mean absolute difference of tau = 0.0036 for eight overlapping wavelengths over three experiment days.

Why it matters

OpenAlex reports 51 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A radiometrically stable, commercially available spectroradiometer was used in conjunction with a simple, custom-designed telescope to make spectrally continuous measurements of solar spectral transmittance and directly transmitted solar spectral irradiance. The wavelength range of the instrument is 350-2500 nm and the resolution is 3-11.7 nm. Laboratory radiometric calibrations show the instrument to be stable to better than 1.0% over a nine-month period. The instrument and telescope are highly portable, can be set up in a matter of minutes, and can be operated by one person. A method of absolute radiometric calibration that can be tied to published top-of-the-atmosphere (TOA) solar spectra in valid Langley channels as well as regions of strong molecular absorption is also presented. High-altitude Langley plot calibration experiments indicate that this technique is limited ultimately by the current uncertainties in the TOA solar spectra, approximately 2-3%. Example comparisons of measured and modtran-modeled direct solar irradiance show that the model can be parameterized to agree with measurements over the large majority of the wavelength range to the 3% level for the two example cases shown. Side-by-side comparisons with a filter-based solar radiometer are in excellent agreement, with a mean absolute difference of tau = 0.0036 for eight overlapping wavelengths over three experiment days.

Key concepts: Irradiance, Spectroradiometer, Optics, MODTRAN, Radiometer, Radiance, Remote sensing, Calibration

Related papers

Back to paper searchBrowse research topicsOriginal source
Direct solar spectral irradiance and transmittance measurements from 350 to 2500 nm — Research Paper | ScholarLens