2020•MetrologiaOpen access

Calibrating spectrometers for measurements of the spectral irradiance caused by solar radiation

Carsten Schinke, Hendrik Pollex, David Hinken, Martin Wolf, Karsten Bothe, Ingo Kröger, Saulius Nevas, Stefan Winter

Open full text 20 citations

Abstract

Abstract Measuring the spectral irradiance of solar radiation is required in many fields of science and technology. In this work, we present an in-depth discussion of the measuring procedure and required corrections for such measurements. We also describe our measurement uncertainty analysis, which is based on a Monte-Carlo procedure in accordance with the Guide to the expression of uncertainty in measurement (JCGM, Paris, 2008). For this purpose, fifteen uncertainty sources are identified, analyzed and described analytically. As a specific application example, we describe the instrumentation and procedure for determining the spectral irradiance of a solar simulator at the ISO/IEC 17 025 accredited solar cell calibration laboratory ISFH CalTeC and the corresponding measurement uncertainty analysis. Moreover, we provide a Python implementation for this calculation along with the paper. We show that for state-of-the-art instrumentation, significant uncertainty contributions arise from the reference lamp (primary calibration standard), stray light and signal-to-noise ratio. If sharp spectral features are present (which is common, e.g. for Xenon lamps), spectral bandwidth and wavelength uncertainty also contribute significantly to the overall uncertainty.

Open-access reader

About this research paper

What this paper is about

Abstract Measuring the spectral irradiance of solar radiation is required in many fields of science and technology. In this work, we present an in-depth discussion of the measuring procedure and required corrections for such measurements. We also describe our measurement uncertainty analysis, which is based on a Monte-Carlo procedure in accordance with the Guide to the expression of uncertainty in measurement (JCGM, Paris, 2008). For this purpose, fifteen uncertainty sources are identified, analyzed and described analytically. As a specific application example, we describe the instrumentation and procedure for determining the spectral irradiance of a solar simulator at the ISO/IEC 17 025 accredited solar cell calibration laboratory ISFH CalTeC and the corresponding measurement uncertainty analysis. Moreover, we provide a Python implementation for this calculation along with the paper. We show that for state-of-the-art instrumentation, significant uncertainty contributions arise from the reference lamp (primary calibration standard), stray light and signal-to-noise ratio. If sharp spectral features are present (which is common, e.g. for Xenon lamps), spectral bandwidth and wavelength uncertainty also contribute significantly to the overall uncertainty.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Measuring the spectral irradiance of solar radiation is required in many fields of science and technology. In this work, we present an in-depth discussion of the measuring procedure and required corrections for such measurements. We also describe our measurement uncertainty analysis, which is based on a Monte-Carlo procedure in accordance with the Guide to the expression of uncertainty in measurement (JCGM, Paris, 2008). For this purpose, fifteen uncertainty sources are identified, analyzed and described analytically. As a specific application example, we describe the instrumentation and procedure for determining the spectral irradiance of a solar simulator at the ISO/IEC 17 025 accredited solar cell calibration laboratory ISFH CalTeC and the corresponding measurement uncertainty analysis. Moreover, we provide a Python implementation for this calculation along with the paper. We show that for state-of-the-art instrumentation, significant uncertainty contributions arise from the reference lamp (primary calibration standard), stray light and signal-to-noise ratio. If sharp spectral features are present (which is common, e.g. for Xenon lamps), spectral bandwidth and wavelength uncertainty also contribute significantly to the overall uncertainty.

Key concepts: Irradiance, Measurement uncertainty, Spectrometer, Instrumentation (computer programming), Optics, Calibration, Metrology, Radiation

Related papers

Back to paper searchBrowse research topicsOriginal source
Calibrating spectrometers for measurements of the spectral irradiance caused by solar radiation — Research Paper | ScholarLens