2007Practical Preventive MedicineRequires access

Determination of Blood Lead by GFAAS Using Improved Matrix Modifier

Xie Hong-bin

Open publisher page 0 citations

Abstract

Objective To develop a modified method for detecting blood lead by GFAAS using an improved matrix modifier,which eliminate the matrix interference effectively.Methods Samples were digested by HNO3+H2O2,and matrix modifier was NH4H2PO4+ HNO3+Vit C,and then detected by GFAAS.Results The recovery rate was 92.7%~100.8%,and relative standard deviation(RSD) was 2.9%~5.7%.The detection limit was 4.2ug/L.This method satisfactory with Blood Lead Clinical Laboratory Technical Specification by Ministry of Health.Conclusion The modified method is simple,convenient,accurate and with good reproducibility.The result is satisfactory.

About this research paper

What this paper is about

Objective To develop a modified method for detecting blood lead by GFAAS using an improved matrix modifier,which eliminate the matrix interference effectively.Methods Samples were digested by HNO3+H2O2,and matrix modifier was NH4H2PO4+ HNO3+Vit C,and then detected by GFAAS.Results The recovery rate was 92.7%~100.8%,and relative standard deviation(RSD) was 2.9%~5.7%.The detection limit was 4.2ug/L.This method satisfactory with Blood Lead Clinical Laboratory Technical Specification by Ministry of Health.Conclusion The modified method is simple,convenient,accurate and with good reproducibility.The result is satisfactory.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To develop a modified method for detecting blood lead by GFAAS using an improved matrix modifier,which eliminate the matrix interference effectively.Methods Samples were digested by HNO3+H2O2,and matrix modifier was NH4H2PO4+ HNO3+Vit C,and then detected by GFAAS.Results The recovery rate was 92.7%~100.8%,and relative standard deviation(RSD) was 2.9%~5.7%.The detection limit was 4.2ug/L.This method satisfactory with Blood Lead Clinical Laboratory Technical Specification by Ministry of Health.Conclusion The modified method is simple,convenient,accurate and with good reproducibility.The result is satisfactory.

Key concepts: Christian ministry, Detection limit, Reproducibility, Matrix (chemical analysis), Recovery rate, Relative standard deviation, Lead (geology), Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Blood Lead by GFAAS Using Improved Matrix Modifier — Research Paper | ScholarLens