2001Zhongguo yaofangRequires access

Determination of Concentration of Fentanyl in Human Plasma by HPLC With UV Detection

Enyou Li

Open publisher page 0 citations

Abstract

OBJECTIVE:To determine the concentration of fentanyl in human plasma by HPLC with ultraviolet detection METHODS:External standard method was used The eluation of fentanyl was carried out by shim-Pack CLC-ODS(6 0mm×150mm,5μm)column with 0 015mol/L NaH2PO4 acetonitril-H2O(30∶70,v/v)as the mobile phase,and detection wavelength was 195nm RESULTS:Calibration curve for fentanyl was linear in the range of 2 0~100ng/ml(r=0 999) The detection limit was 1 0ng/ml The within-day RSD was (6 50±2 79)%,the between-day RSD Was (6 70±3 04)% The method recovery was (91 70±4 70)% The extraction recovery was (97 38±3 69)% CONCLUSION:This method was quick and accurate for the determination of fentanyl in human plasma and useful for pharmakinetic study of fentanyl

About this research paper

What this paper is about

OBJECTIVE:To determine the concentration of fentanyl in human plasma by HPLC with ultraviolet detection METHODS:External standard method was used The eluation of fentanyl was carried out by shim-Pack CLC-ODS(6 0mm×150mm,5μm)column with 0 015mol/L NaH2PO4 acetonitril-H2O(30∶70,v/v)as the mobile phase,and detection wavelength was 195nm RESULTS:Calibration curve for fentanyl was linear in the range of 2 0~100ng/ml(r=0 999) The detection limit was 1 0ng/ml The within-day RSD was (6 50±2 79)%,the between-day RSD Was (6 70±3 04)% The method recovery was (91 70±4 70)% The extraction recovery was (97 38±3 69)% CONCLUSION:This method was quick and accurate for the determination of fentanyl in human plasma and useful for pharmakinetic study of fentanyl

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE:To determine the concentration of fentanyl in human plasma by HPLC with ultraviolet detection METHODS:External standard method was used The eluation of fentanyl was carried out by shim-Pack CLC-ODS(6 0mm×150mm,5μm)column with 0 015mol/L NaH2PO4 acetonitril-H2O(30∶70,v/v)as the mobile phase,and detection wavelength was 195nm RESULTS:Calibration curve for fentanyl was linear in the range of 2 0~100ng/ml(r=0 999) The detection limit was 1 0ng/ml The within-day RSD was (6 50±2 79)%,the between-day RSD Was (6 70±3 04)% The method recovery was (91 70±4 70)% The extraction recovery was (97 38±3 69)% CONCLUSION:This method was quick and accurate for the determination of fentanyl in human plasma and useful for pharmakinetic study of fentanyl

Key concepts: Fentanyl, Chromatography, Calibration curve, Detection limit, Human plasma, High-performance liquid chromatography, Chemistry, Linear range

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Concentration of Fentanyl in Human Plasma by HPLC With UV Detection — Research Paper | ScholarLens