Initial evaluation of the ACL-Futura coagulation analyzer

Peng Chang-hu

Open publisher page 0 citations

Abstract

Objective: To evaluate the technical performance of the ACL-Futura coagulation analyzer.And to provide data for various laboratories in the selection of coagulation analyzer.Methods: To co-evaluated the following assay:Prothrombin time(PT),Activated partial thromboplaslin time(APTT),Fibrinogen-C(Fbg-C,Clauss method),Fibrinogen-D(Fbg-D,Derived method) and Glycated Hemoglobin A1c(GHbA1c,Lactic-gel agglomerate method).The precision,stability,accuracy,linearity and interferences were assessed.Results:The analyzer shows an within-between day imprecision with normal control plasma,for PT of 1.0 to 1.3%,APTT of 1.8 to 3.8%,Fibrinogen-C of 2.4 to 3.3%,Fibrinogen-D of 1.4 to 1.5% and GHbA1c of 4.4 to 7.6% respectively.The calibration curves were linear within the concentration range of 1.75-5.31mg/L for Fbg-C,0.67-2.67mg/L for Fbg-D and 1.44-14.4 for GHbA1c(r0.998,P0.01).In addition,the correlation between the dilution of sample and the result(second) of APTT and PT is good(n=6,r0.999,P0.01).Experimental results also show that relative deviations of ATTT,PT,Fbg-C and Fbg-D were 3.9%,0.6%.0.6% and 0.4% respectively.It is not significantly affected by such biological products as haemoglobin,bilirubin and triglycerides up to 4.0g/L,127.3μmol/L and 6.36mmol/L respectively.Conclusion: Instrument is reliable,precision,easy to use and capable of fast sample throughput.

About this research paper

What this paper is about

Objective: To evaluate the technical performance of the ACL-Futura coagulation analyzer.And to provide data for various laboratories in the selection of coagulation analyzer.Methods: To co-evaluated the following assay:Prothrombin time(PT),Activated partial thromboplaslin time(APTT),Fibrinogen-C(Fbg-C,Clauss method),Fibrinogen-D(Fbg-D,Derived method) and Glycated Hemoglobin A1c(GHbA1c,Lactic-gel agglomerate method).The precision,stability,accuracy,linearity and interferences were assessed.Results:The analyzer shows an within-between day imprecision with normal control plasma,for PT of 1.0 to 1.3%,APTT of 1.8 to 3.8%,Fibrinogen-C of 2.4 to 3.3%,Fibrinogen-D of 1.4 to 1.5% and GHbA1c of 4.4 to 7.6% respectively.The calibration curves were linear within the concentration range of 1.75-5.31mg/L for Fbg-C,0.67-2.67mg/L for Fbg-D and 1.44-14.4 for GHbA1c(r0.998,P0.01).In addition,the correlation between the dilution of sample and the result(second) of APTT and PT is good(n=6,r0.999,P0.01).Experimental results also show that relative deviations of ATTT,PT,Fbg-C and Fbg-D were 3.9%,0.6%.0.6% and 0.4% respectively.It is not significantly affected by such biological products as haemoglobin,bilirubin and triglycerides up to 4.0g/L,127.3μmol/L and 6.36mmol/L respectively.Conclusion: Instrument is reliable,precision,easy to use and capable of fast sample throughput.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To evaluate the technical performance of the ACL-Futura coagulation analyzer.And to provide data for various laboratories in the selection of coagulation analyzer.Methods: To co-evaluated the following assay:Prothrombin time(PT),Activated partial thromboplaslin time(APTT),Fibrinogen-C(Fbg-C,Clauss method),Fibrinogen-D(Fbg-D,Derived method) and Glycated Hemoglobin A1c(GHbA1c,Lactic-gel agglomerate method).The precision,stability,accuracy,linearity and interferences were assessed.Results:The analyzer shows an within-between day imprecision with normal control plasma,for PT of 1.0 to 1.3%,APTT of 1.8 to 3.8%,Fibrinogen-C of 2.4 to 3.3%,Fibrinogen-D of 1.4 to 1.5% and GHbA1c of 4.4 to 7.6% respectively.The calibration curves were linear within the concentration range of 1.75-5.31mg/L for Fbg-C,0.67-2.67mg/L for Fbg-D and 1.44-14.4 for GHbA1c(r0.998,P0.01).In addition,the correlation between the dilution of sample and the result(second) of APTT and PT is good(n=6,r0.999,P0.01).Experimental results also show that relative deviations of ATTT,PT,Fbg-C and Fbg-D were 3.9%,0.6%.0.6% and 0.4% respectively.It is not significantly affected by such biological products as haemoglobin,bilirubin and triglycerides up to 4.0g/L,127.3μmol/L and 6.36mmol/L respectively.Conclusion: Instrument is reliable,precision,easy to use and capable of fast sample throughput.

Key concepts: Spectrum analyzer, Chromatography, Fibrinogen, Prothrombin time, Coagulation, Calibration curve, Chemistry, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Initial evaluation of the ACL-Futura coagulation analyzer — Research Paper | ScholarLens