Performance Evaluation of IL ACL 7000 Coagulation Analyzer System

WU Shao-guo

Open publisher page 0 citations

Abstract

Objective To conduct a comprehensive performance evaluation of IL ACL 7000 Fully Automated Coagulation Analyzer used for two years in the laboratory.Methods With professional and technical programs released by the International Council for Standardization in Haematology(ICSH),fresh plasma,mixed plasma,plasma prothrombin time(PT),activated partial thromboplastin time(APTT),thrombin time(TT),fibrinogen(Fib) and other projects were detected in the apparatus to evaluate the precision,accuracy,linear range and carrying stain rate,etc.Results The intra-inter-assay precisions of PT(s),APTT(s),TT(s) and Fib(g / L) were 0.69% ~ 2.18%,0.86% ~ 3.43% respectively,relative bias(Bias%) was 1.6% ~ 3.0%,the average recovery was 98.1%,carrying stain rate was 0.4% ~ 1.0%.Conclusions IL ACL 7000 Coagulation Analyzer used for two years still has high precision and accuracy,and also has a good linear range,which may fully provide accurate detection results for clinic.

About this research paper

What this paper is about

Objective To conduct a comprehensive performance evaluation of IL ACL 7000 Fully Automated Coagulation Analyzer used for two years in the laboratory.Methods With professional and technical programs released by the International Council for Standardization in Haematology(ICSH),fresh plasma,mixed plasma,plasma prothrombin time(PT),activated partial thromboplastin time(APTT),thrombin time(TT),fibrinogen(Fib) and other projects were detected in the apparatus to evaluate the precision,accuracy,linear range and carrying stain rate,etc.Results The intra-inter-assay precisions of PT(s),APTT(s),TT(s) and Fib(g / L) were 0.69% ~ 2.18%,0.86% ~ 3.43% respectively,relative bias(Bias%) was 1.6% ~ 3.0%,the average recovery was 98.1%,carrying stain rate was 0.4% ~ 1.0%.Conclusions IL ACL 7000 Coagulation Analyzer used for two years still has high precision and accuracy,and also has a good linear range,which may fully provide accurate detection results for clinic.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To conduct a comprehensive performance evaluation of IL ACL 7000 Fully Automated Coagulation Analyzer used for two years in the laboratory.Methods With professional and technical programs released by the International Council for Standardization in Haematology(ICSH),fresh plasma,mixed plasma,plasma prothrombin time(PT),activated partial thromboplastin time(APTT),thrombin time(TT),fibrinogen(Fib) and other projects were detected in the apparatus to evaluate the precision,accuracy,linear range and carrying stain rate,etc.Results The intra-inter-assay precisions of PT(s),APTT(s),TT(s) and Fib(g / L) were 0.69% ~ 2.18%,0.86% ~ 3.43% respectively,relative bias(Bias%) was 1.6% ~ 3.0%,the average recovery was 98.1%,carrying stain rate was 0.4% ~ 1.0%.Conclusions IL ACL 7000 Coagulation Analyzer used for two years still has high precision and accuracy,and also has a good linear range,which may fully provide accurate detection results for clinic.

Key concepts: Medicine, Partial thromboplastin time, Spectrum analyzer, Fibrinogen, Prothrombin time, Thrombin time, Coagulation, Reference range

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance Evaluation of IL ACL 7000 Coagulation Analyzer System — Research Paper | ScholarLens