2011Zhōnghuá yàoxué zázhìRequires access

Simultaneous Determination of Four Effective Components in Huaijiao Pills by RP-HPLC

Xiaoliang Wei

Open publisher page 2 citations

Abstract

OBJECTIVE To develop a RP-HPLC method for the determination of sophoricosid,baicalin,genistein and wogonin in Huaijiao pills.METHODS A Diamonsil C18 column(4.6 mm×200 mm,5μm) was used at 30 ℃.The mobile phase consisted of acetonitrile-0.05% phosphoric acid aqueous under gradient elution(0-10 min,25%-37% acetonitrile;10-25 min,37%-60% acetonitrile).The flow rate was set at 1.0 mL·min-1.The detection wavelength was 260 nm.RESULTS The linearities ranged in 11.6-116 μg·mL-1 for sophoricosid(r=0 999 6,n=6),33.5-335 μg·mL-1 for baicalin(r=0.999 8,n=6),0.46-4.63 μg·mL-1 for genistein(r=0.999 8,n=6),1.54-15.4 μg·mL-1 for wogonin(r=0.999 7,n=6) respectively.Recoveries were 99.3% with RSD 1.1% for sophoricosid,99.6% with RSD 1.1% for baicalin,99.6% with RSD 1.4% for genistein,99.0% with RSD 0.8% for wogonin.CONCLUSION The method is quick,simple and repeatable for simultaneous determination of sophoricosid,baicalin,genistein and wogonin in Huaijiao pills.

About this research paper

What this paper is about

OBJECTIVE To develop a RP-HPLC method for the determination of sophoricosid,baicalin,genistein and wogonin in Huaijiao pills.METHODS A Diamonsil C18 column(4.6 mm×200 mm,5μm) was used at 30 ℃.The mobile phase consisted of acetonitrile-0.05% phosphoric acid aqueous under gradient elution(0-10 min,25%-37% acetonitrile;10-25 min,37%-60% acetonitrile).The flow rate was set at 1.0 mL·min-1.The detection wavelength was 260 nm.RESULTS The linearities ranged in 11.6-116 μg·mL-1 for sophoricosid(r=0 999 6,n=6),33.5-335 μg·mL-1 for baicalin(r=0.999 8,n=6),0.46-4.63 μg·mL-1 for genistein(r=0.999 8,n=6),1.54-15.4 μg·mL-1 for wogonin(r=0.999 7,n=6) respectively.Recoveries were 99.3% with RSD 1.1% for sophoricosid,99.6% with RSD 1.1% for baicalin,99.6% with RSD 1.4% for genistein,99.0% with RSD 0.8% for wogonin.CONCLUSION The method is quick,simple and repeatable for simultaneous determination of sophoricosid,baicalin,genistein and wogonin in Huaijiao pills.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE To develop a RP-HPLC method for the determination of sophoricosid,baicalin,genistein and wogonin in Huaijiao pills.METHODS A Diamonsil C18 column(4.6 mm×200 mm,5μm) was used at 30 ℃.The mobile phase consisted of acetonitrile-0.05% phosphoric acid aqueous under gradient elution(0-10 min,25%-37% acetonitrile;10-25 min,37%-60% acetonitrile).The flow rate was set at 1.0 mL·min-1.The detection wavelength was 260 nm.RESULTS The linearities ranged in 11.6-116 μg·mL-1 for sophoricosid(r=0 999 6,n=6),33.5-335 μg·mL-1 for baicalin(r=0.999 8,n=6),0.46-4.63 μg·mL-1 for genistein(r=0.999 8,n=6),1.54-15.4 μg·mL-1 for wogonin(r=0.999 7,n=6) respectively.Recoveries were 99.3% with RSD 1.1% for sophoricosid,99.6% with RSD 1.1% for baicalin,99.6% with RSD 1.4% for genistein,99.0% with RSD 0.8% for wogonin.CONCLUSION The method is quick,simple and repeatable for simultaneous determination of sophoricosid,baicalin,genistein and wogonin in Huaijiao pills.

Key concepts: Baicalin, Wogonin, Chromatography, Chemistry, High-performance liquid chromatography, Phosphoric acid, Genistein, Acetonitrile

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous Determination of Four Effective Components in Huaijiao Pills by RP-HPLC — Research Paper | ScholarLens