HPLC-ELSD simultaneous determination of monosaccharide and sucrose in Delisheng injection
Guoan Luo
Abstract
Guoan Luo
Abstract
Objective:To establish an HPLC with evaporative light scattering detection(HPLC-ELSD) method for the simultaneous quantitative analysis of fructose,glucose,sucrose in Delisheng injection.Methods:The optimal conditions of separation and detection were achieved on an analytical column specially for sugar with a mobile phase composed of a mixture of acetonitrile and 10 mmol·L-1 ammonium acetate at a flow rate of 1 mL·min-1 by gradient elution.Detector was ELSD and column temperature was 30 ℃.The ELSD drift tube temperature was 85 ℃ and the flow rate of the dry gas was 2.1 L·min-1.Results:Under the above conditions,all fructose,glucose,sucrose could be well separated.The linear ranges of fructose,glucose and sucrose of 1.024-63.98 μg,1.032-64.52 μg and 0.4040-25.22 μg.The average recoveries(n = 9) were 95%-105%,RSD were less than 5%.Conclusion:This method is reliable,simple and reproducible,thus it is suitable for the determination of monosaccharide and sucrose in Delisheng injection,and can provide the reference of the quality control for Delisheng injection.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To establish an HPLC with evaporative light scattering detection(HPLC-ELSD) method for the simultaneous quantitative analysis of fructose,glucose,sucrose in Delisheng injection.Methods:The optimal conditions of separation and detection were achieved on an analytical column specially for sugar with a mobile phase composed of a mixture of acetonitrile and 10 mmol·L-1 ammonium acetate at a flow rate of 1 mL·min-1 by gradient elution.Detector was ELSD and column temperature was 30 ℃.The ELSD drift tube temperature was 85 ℃ and the flow rate of the dry gas was 2.1 L·min-1.Results:Under the above conditions,all fructose,glucose,sucrose could be well separated.The linear ranges of fructose,glucose and sucrose of 1.024-63.98 μg,1.032-64.52 μg and 0.4040-25.22 μg.The average recoveries(n = 9) were 95%-105%,RSD were less than 5%.Conclusion:This method is reliable,simple and reproducible,thus it is suitable for the determination of monosaccharide and sucrose in Delisheng injection,and can provide the reference of the quality control for Delisheng injection.
Key concepts: Chemistry, Chromatography detector, Chromatography, Fructose, Sucrose, Monosaccharide, High-performance liquid chromatography, Ammonium acetate