[Kinetic spectrophotometric determination of trace chromium(VI) with sensitized function of microemulsion].
Ping Yu, Junjie Gao, Song En-jun
Abstract
Ping Yu, Junjie Gao, Song En-jun
Abstract
A sensitive catalytic spectrophotometric method for determining microg x L(-1) of chromium(VI) has been developed. The method, based on the catalytic effect of Cr(VI)on the oxidation of aligarin red with hydrogen peroxide, was monitored spctrophotornetrically in the medium of microemulsion which consists of CTMAB, n-pentanol, n-heptane and water. The variables affecting the rate of the reaction were investigated. The linearity range of the calibration graph is dependent on the reaction temperature. The sensitivity of this method is 72.5% higher in the microemulsion medium than in CTMAB medium. The apparent active energy of the catalytic reaction is 55.7 kJ x mol(-1). The calibration graph is linear for 2.4-75 microg x L(-1) Cr(VI)at 80 degrees C, the detection limit is 4.27 x 10(-10) g x mL(-1), and the relative standard deviation of eleven determinations of 60 microg x L(-1) Cr(VI)was 1.84%. The method has been successfully applied to the determination of chromium(IV) in the electroplating waste water.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A sensitive catalytic spectrophotometric method for determining microg x L(-1) of chromium(VI) has been developed. The method, based on the catalytic effect of Cr(VI)on the oxidation of aligarin red with hydrogen peroxide, was monitored spctrophotornetrically in the medium of microemulsion which consists of CTMAB, n-pentanol, n-heptane and water. The variables affecting the rate of the reaction were investigated. The linearity range of the calibration graph is dependent on the reaction temperature. The sensitivity of this method is 72.5% higher in the microemulsion medium than in CTMAB medium. The apparent active energy of the catalytic reaction is 55.7 kJ x mol(-1). The calibration graph is linear for 2.4-75 microg x L(-1) Cr(VI)at 80 degrees C, the detection limit is 4.27 x 10(-10) g x mL(-1), and the relative standard deviation of eleven determinations of 60 microg x L(-1) Cr(VI)was 1.84%. The method has been successfully applied to the determination of chromium(IV) in the electroplating waste water.
Key concepts: Chromium, Microemulsion, Chemistry, Detection limit, Catalysis, Calibration curve, Hydrogen peroxide, Analytical Chemistry (journal)