2012•Yaowu fenxi zazhiRequires access

Comparison of chromium determination in capsule shells by Zeeman flame and graphite furnace atomic absorption spectrophotometry

Xuelin Liu

Open publisher page 0 citations

Abstract

Objective:To investigate effects of Zeeman flame atomic absorption spectrophotometry(AAS) and graphite furnace AAS on the determination of chromium in capsule shells.Methods:Microwave digestion was adopted to digest the capsule shells.Zeeman effect was used in the background correction.The slit width was set at 1.3 nm,lamp current 7.5 mA,and the content of chromium was determined at a wavelength of 359.3 nm by Zeeman flame AAS and graphite furnace AAS respectively.Results:For the Zeeman flame AAS method,the calibration curve was linear in the range of 0-1.0 μg·mL-1(r=0.9998),the detection limit was 5.26 ng·mL-1,RSD was 0.68%-1.0% and the average recovery was 100.0%-116.7%.For the graphite furnace AAS method,the calibration curve was linear in the range of 0-20 ng·mL-1(r=0.9999),the detection limit was 0.26 ng·mL-1,RSD was 1.7%-4.9% and the average recovery was 98.2%-105.6%.Conclusion:The Zeeman flame AAS method is simple,fast,and suitable for the preliminary determination of chromium in capsule shells in emergent cases;the graphite furnace AAS method is sensitive,accurate,and suitable for the determination of chromium in capsule shells in any case.

About this research paper

What this paper is about

Objective:To investigate effects of Zeeman flame atomic absorption spectrophotometry(AAS) and graphite furnace AAS on the determination of chromium in capsule shells.Methods:Microwave digestion was adopted to digest the capsule shells.Zeeman effect was used in the background correction.The slit width was set at 1.3 nm,lamp current 7.5 mA,and the content of chromium was determined at a wavelength of 359.3 nm by Zeeman flame AAS and graphite furnace AAS respectively.Results:For the Zeeman flame AAS method,the calibration curve was linear in the range of 0-1.0 μg·mL-1(r=0.9998),the detection limit was 5.26 ng·mL-1,RSD was 0.68%-1.0% and the average recovery was 100.0%-116.7%.For the graphite furnace AAS method,the calibration curve was linear in the range of 0-20 ng·mL-1(r=0.9999),the detection limit was 0.26 ng·mL-1,RSD was 1.7%-4.9% and the average recovery was 98.2%-105.6%.Conclusion:The Zeeman flame AAS method is simple,fast,and suitable for the preliminary determination of chromium in capsule shells in emergent cases;the graphite furnace AAS method is sensitive,accurate,and suitable for the determination of chromium in capsule shells in any case.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To investigate effects of Zeeman flame atomic absorption spectrophotometry(AAS) and graphite furnace AAS on the determination of chromium in capsule shells.Methods:Microwave digestion was adopted to digest the capsule shells.Zeeman effect was used in the background correction.The slit width was set at 1.3 nm,lamp current 7.5 mA,and the content of chromium was determined at a wavelength of 359.3 nm by Zeeman flame AAS and graphite furnace AAS respectively.Results:For the Zeeman flame AAS method,the calibration curve was linear in the range of 0-1.0 μg·mL-1(r=0.9998),the detection limit was 5.26 ng·mL-1,RSD was 0.68%-1.0% and the average recovery was 100.0%-116.7%.For the graphite furnace AAS method,the calibration curve was linear in the range of 0-20 ng·mL-1(r=0.9999),the detection limit was 0.26 ng·mL-1,RSD was 1.7%-4.9% and the average recovery was 98.2%-105.6%.Conclusion:The Zeeman flame AAS method is simple,fast,and suitable for the preliminary determination of chromium in capsule shells in emergent cases;the graphite furnace AAS method is sensitive,accurate,and suitable for the determination of chromium in capsule shells in any case.

Key concepts: Graphite furnace atomic absorption, Chemistry, Chromium, Calibration curve, Detection limit, Analytical Chemistry (journal), Graphite, Zeeman effect

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of chromium determination in capsule shells by Zeeman flame and graphite furnace atomic absorption spectrophotometry — Research Paper | ScholarLens