2001•The AnalystRequires access

Synchronous fluorescence and absorbance dynamic liquid drop sensor for Cr(vi) determination at the femtomole level

Dan Xiao, Kemin Wang, Wenxiang Xiao

Open publisher page 18 citations

Abstract

A novel synchronous fluorimetric and absorptiometric technique based on dynamic liquid drops coupled with flow injection is described for the determination of chromium(VI) in aqueous solutions. Drops formed continuously at the end of a quartz capillary tube serve as reactor and optical cell. The reaction between chromium(VI) and 3,3',5,5'-tetramethylbenzidine dichloride (TMB-d) results in a significant decrease in fluorescence and transmitted light intensity, proportional to the logarithm of the concentration of chromium(VI). The transmitted light and fluorescence emission are detected in counter and perpendicular positions of the excitation light by a photomultipler tube and photodiode, respectively. In HCl-NaOAc buffer solution (pH 3.29), the sensor has a wide linear calibration range of 2 x 10(-8)-1 x 10(-4) mol l(-1) chromium(VI) with an absolute mass detection limit of 12.88 fmol.

About this research paper

What this paper is about

A novel synchronous fluorimetric and absorptiometric technique based on dynamic liquid drops coupled with flow injection is described for the determination of chromium(VI) in aqueous solutions. Drops formed continuously at the end of a quartz capillary tube serve as reactor and optical cell. The reaction between chromium(VI) and 3,3',5,5'-tetramethylbenzidine dichloride (TMB-d) results in a significant decrease in fluorescence and transmitted light intensity, proportional to the logarithm of the concentration of chromium(VI). The transmitted light and fluorescence emission are detected in counter and perpendicular positions of the excitation light by a photomultipler tube and photodiode, respectively. In HCl-NaOAc buffer solution (pH 3.29), the sensor has a wide linear calibration range of 2 x 10(-8)-1 x 10(-4) mol l(-1) chromium(VI) with an absolute mass detection limit of 12.88 fmol.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A novel synchronous fluorimetric and absorptiometric technique based on dynamic liquid drops coupled with flow injection is described for the determination of chromium(VI) in aqueous solutions. Drops formed continuously at the end of a quartz capillary tube serve as reactor and optical cell. The reaction between chromium(VI) and 3,3',5,5'-tetramethylbenzidine dichloride (TMB-d) results in a significant decrease in fluorescence and transmitted light intensity, proportional to the logarithm of the concentration of chromium(VI). The transmitted light and fluorescence emission are detected in counter and perpendicular positions of the excitation light by a photomultipler tube and photodiode, respectively. In HCl-NaOAc buffer solution (pH 3.29), the sensor has a wide linear calibration range of 2 x 10(-8)-1 x 10(-4) mol l(-1) chromium(VI) with an absolute mass detection limit of 12.88 fmol.

Key concepts: Chromium, Absorbance, Chemistry, Detection limit, Analytical Chemistry (journal), Fluorescence, Photodiode, Calibration curve

Related papers

Back to paper searchBrowse research topicsOriginal source
Synchronous fluorescence and absorbance dynamic liquid drop sensor for Cr(vi) determination at the femtomole level — Research Paper | ScholarLens