2008•Food ScienceRequires access

Study on Determination of Melamine in Fresh Milk and Dairy Product by High Performance Liquid Chromatography

Zhaohui Hu

Open publisher page 1 citations

Abstract

A high performance liquid chromatography-photodiode array detector for determining the content of melamine in fresh milk and dairy produce was studied. Referring to FDA method and NY/T 1372—2007 of determination melamine,the chromatogram conditions for determining the content of melamine were discussed and the predisposal method of melamine in fresh milk and dairy product was optimized. The optimal detection conditions are determined as follows: 0. 02mol/L ammonium sulfate-methanol (94: 6,V/V) as mobile phase,and detection wavelength 203 nm. The good linearity is in the range of from 0.1 to 150 μg/ml,the detection limit is 0.5 mg/kg,the average recoveries of melamine are above 91%,and the regression equation is y=2.37×105x+1.21×104 with the coefficient 0.9998. The method is simple,rapid,sensitive and exact with convenient sample treatment method feasible. It is suitable for the determination of melamine in fresh milk and dairy product.

About this research paper

What this paper is about

A high performance liquid chromatography-photodiode array detector for determining the content of melamine in fresh milk and dairy produce was studied. Referring to FDA method and NY/T 1372—2007 of determination melamine,the chromatogram conditions for determining the content of melamine were discussed and the predisposal method of melamine in fresh milk and dairy product was optimized. The optimal detection conditions are determined as follows: 0. 02mol/L ammonium sulfate-methanol (94: 6,V/V) as mobile phase,and detection wavelength 203 nm. The good linearity is in the range of from 0.1 to 150 μg/ml,the detection limit is 0.5 mg/kg,the average recoveries of melamine are above 91%,and the regression equation is y=2.37×105x+1.21×104 with the coefficient 0.9998. The method is simple,rapid,sensitive and exact with convenient sample treatment method feasible. It is suitable for the determination of melamine in fresh milk and dairy product.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A high performance liquid chromatography-photodiode array detector for determining the content of melamine in fresh milk and dairy produce was studied. Referring to FDA method and NY/T 1372—2007 of determination melamine,the chromatogram conditions for determining the content of melamine were discussed and the predisposal method of melamine in fresh milk and dairy product was optimized. The optimal detection conditions are determined as follows: 0. 02mol/L ammonium sulfate-methanol (94: 6,V/V) as mobile phase,and detection wavelength 203 nm. The good linearity is in the range of from 0.1 to 150 μg/ml,the detection limit is 0.5 mg/kg,the average recoveries of melamine are above 91%,and the regression equation is y=2.37×105x+1.21×104 with the coefficient 0.9998. The method is simple,rapid,sensitive and exact with convenient sample treatment method feasible. It is suitable for the determination of melamine in fresh milk and dairy product.

Key concepts: Melamine, Chromatography, Chemistry, Detection limit, High-performance liquid chromatography, Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on Determination of Melamine in Fresh Milk and Dairy Product by High Performance Liquid Chromatography — Research Paper | ScholarLens