2009•Anhui Journal of Preventive MedicineRequires access

A Fast analysis of melamine in milk and its products with high performance liquid chromatography

Yanping Li

Open publisher page 0 citations

Abstract

Objective To establish a fast high performance liquid chromatography(HPLC) method for determination of melamine in milk and dairy products.Methods Melamine in milk and dairy products was extracted by acetonitrile,then separated used ZORBAX Eclipse XDB—C8 column(250×4.6mm,5μm) and the mobile phase consisted of acetonitrile-sodium heptanesulfonate,finally analyzed by HPLC with photodiode array detector(PAD).Results The linear range of calibration curves were in rang of 1~50μg/mL,the correlation coefficient r0.9999,the recovery of standard addition were in rang of 93%~105%,the relative standard deviation(RSD) was 0.66% and the limits of detection were 1mg/kg for milk powder and 0.5 mg/kg for liquid milk products,respectively.Conclusion The results showed this method was simpl and rapid and it is adaptable to detect melamine in these products for factory inspection.

About this research paper

What this paper is about

Objective To establish a fast high performance liquid chromatography(HPLC) method for determination of melamine in milk and dairy products.Methods Melamine in milk and dairy products was extracted by acetonitrile,then separated used ZORBAX Eclipse XDB—C8 column(250×4.6mm,5μm) and the mobile phase consisted of acetonitrile-sodium heptanesulfonate,finally analyzed by HPLC with photodiode array detector(PAD).Results The linear range of calibration curves were in rang of 1~50μg/mL,the correlation coefficient r0.9999,the recovery of standard addition were in rang of 93%~105%,the relative standard deviation(RSD) was 0.66% and the limits of detection were 1mg/kg for milk powder and 0.5 mg/kg for liquid milk products,respectively.Conclusion The results showed this method was simpl and rapid and it is adaptable to detect melamine in these products for factory inspection.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a fast high performance liquid chromatography(HPLC) method for determination of melamine in milk and dairy products.Methods Melamine in milk and dairy products was extracted by acetonitrile,then separated used ZORBAX Eclipse XDB—C8 column(250×4.6mm,5μm) and the mobile phase consisted of acetonitrile-sodium heptanesulfonate,finally analyzed by HPLC with photodiode array detector(PAD).Results The linear range of calibration curves were in rang of 1~50μg/mL,the correlation coefficient r0.9999,the recovery of standard addition were in rang of 93%~105%,the relative standard deviation(RSD) was 0.66% and the limits of detection were 1mg/kg for milk powder and 0.5 mg/kg for liquid milk products,respectively.Conclusion The results showed this method was simpl and rapid and it is adaptable to detect melamine in these products for factory inspection.

Key concepts: Melamine, High-performance liquid chromatography, Chromatography, Calibration curve, Acetonitrile, Relative standard deviation, Chemistry, Correlation coefficient

Related papers

Back to paper searchBrowse research topicsOriginal source
A Fast analysis of melamine in milk and its products with high performance liquid chromatography — Research Paper | ScholarLens