2011Journal of Yunnan University of NationalitiesRequires access

Determination of Chlorogenic Acid Extracted from Flos Lonicerae with High-Speed Homogenization and High Performance Liquid Chromatography

Qiu‐Fen Hu

Open publisher page 0 citations

Abstract

In this paper,three sample preparation for determination of chlorogenic acid in flos lonicerae was studied.Test results showed that the time spent on high-speed homogenization extraction was obviously less than the ultrasonic extraction and the hot reflux extraction.The chlorogenic acid was extracted from samples by high-speed homogenization with 80% methanol solution.The extract was separated on a Waters Xterra RP18 column(3.9mm×150 mm,5 μm) using 1% acetic acid as the mobile phase with gradient elution,the flow rate was 0.8 mL/min.The detection wavelength was 345 nm.Under this condition,the linear of chlorogenic acid was in the range of 5.0—200 μg/mL.The average recoveries of the samples were 118%,and the relative standard deviation was 4.5%(n=6).This method for the extraction and determination of chlorogenic acid in flos lonicerae has good results.

About this research paper

What this paper is about

In this paper,three sample preparation for determination of chlorogenic acid in flos lonicerae was studied.Test results showed that the time spent on high-speed homogenization extraction was obviously less than the ultrasonic extraction and the hot reflux extraction.The chlorogenic acid was extracted from samples by high-speed homogenization with 80% methanol solution.The extract was separated on a Waters Xterra RP18 column(3.9mm×150 mm,5 μm) using 1% acetic acid as the mobile phase with gradient elution,the flow rate was 0.8 mL/min.The detection wavelength was 345 nm.Under this condition,the linear of chlorogenic acid was in the range of 5.0—200 μg/mL.The average recoveries of the samples were 118%,and the relative standard deviation was 4.5%(n=6).This method for the extraction and determination of chlorogenic acid in flos lonicerae has good results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper,three sample preparation for determination of chlorogenic acid in flos lonicerae was studied.Test results showed that the time spent on high-speed homogenization extraction was obviously less than the ultrasonic extraction and the hot reflux extraction.The chlorogenic acid was extracted from samples by high-speed homogenization with 80% methanol solution.The extract was separated on a Waters Xterra RP18 column(3.9mm×150 mm,5 μm) using 1% acetic acid as the mobile phase with gradient elution,the flow rate was 0.8 mL/min.The detection wavelength was 345 nm.Under this condition,the linear of chlorogenic acid was in the range of 5.0—200 μg/mL.The average recoveries of the samples were 118%,and the relative standard deviation was 4.5%(n=6).This method for the extraction and determination of chlorogenic acid in flos lonicerae has good results.

Key concepts: Flos, Chlorogenic acid, Chromatography, Homogenization (climate), Chemistry, High-performance liquid chromatography, Acetic acid, Extraction (chemistry)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Chlorogenic Acid Extracted from Flos Lonicerae with High-Speed Homogenization and High Performance Liquid Chromatography — Research Paper | ScholarLens