Development of a spherical tissue equivalent proportional counter for neutron monitoring
姜志刚, Yuan Yong Gang, 王和义, 陈华
Abstract
姜志刚, Yuan Yong Gang, 王和义, 陈华
Abstract
A spherical tissue equivalent proportional counter(TEPC) for neutron monitoring has been developed. It was properly designed to produce a uniform electric field intensity around the anode wire. An internal 241Am alpha source was adopted for lineal energy calibration. The TEPC was characterized in terms of dose equivalent response in a standard 252Cf neutron field, and was tested with 2.45 MeV neutrons. Microdosimetric spectra, frequency mean lineal energy and dose-average mean lineal energy of 2.45 MeV neutrons were obtained and compared with FLUKA Monte Carlo simulation results. The measurement and simulation results agreed well. The mean quality factor and dose equivalent values evaluated from the 2.45 MeV neutron measurement were in good agreement with the recommended effective quality factor and ambient dose equivalent H*(10),respectively. Preliminary results have proved the availability of the developed TEPC for neutron monitoring.
OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A spherical tissue equivalent proportional counter(TEPC) for neutron monitoring has been developed. It was properly designed to produce a uniform electric field intensity around the anode wire. An internal 241Am alpha source was adopted for lineal energy calibration. The TEPC was characterized in terms of dose equivalent response in a standard 252Cf neutron field, and was tested with 2.45 MeV neutrons. Microdosimetric spectra, frequency mean lineal energy and dose-average mean lineal energy of 2.45 MeV neutrons were obtained and compared with FLUKA Monte Carlo simulation results. The measurement and simulation results agreed well. The mean quality factor and dose equivalent values evaluated from the 2.45 MeV neutron measurement were in good agreement with the recommended effective quality factor and ambient dose equivalent H*(10),respectively. Preliminary results have proved the availability of the developed TEPC for neutron monitoring.
Key concepts: Proportional counter, Equivalent dose, Neutron, Physics, Neutron source, Monte Carlo method, Bonner sphere, Nuclear physics