A tissue equivalent proportional counter filled with a mixture of tissue equivalent gas and 3He for neutron monitoring
Quang Chau, Stéphanie Ménard
Abstract
Quang Chau, Stéphanie Ménard
Abstract
Tissue equivalent proportional counters (TEPC) allow the measurement of the ambient dose equivalent H(*)(10) in mixed fields. IRSN has been studying the design and the response of a TEPC in terms of neutron H(*)(10). First, a cylindrical counter was filled with propane gas at a low pressure. H(*)(10) measured in monoenergetic neutron fields underestimated the reference (>50%) at low energies (< 500 keV). A small amount of (3)He was then added to the gas in order to increase the response. The underestimation observed decreased but the results (> 40%) were not totally complying with the objectives (< 20%). Finally the choice was made to improve the analysis of the microdosimetric spectra y.d(y) in order to identify the energy of the incident neutrons. The analysis allows a better estimate of H(*)(10). The aim of this article is to describe the TEPC and the effect of these methods of optimisation.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Tissue equivalent proportional counters (TEPC) allow the measurement of the ambient dose equivalent H(*)(10) in mixed fields. IRSN has been studying the design and the response of a TEPC in terms of neutron H(*)(10). First, a cylindrical counter was filled with propane gas at a low pressure. H(*)(10) measured in monoenergetic neutron fields underestimated the reference (>50%) at low energies (< 500 keV). A small amount of (3)He was then added to the gas in order to increase the response. The underestimation observed decreased but the results (> 40%) were not totally complying with the objectives (< 20%). Finally the choice was made to improve the analysis of the microdosimetric spectra y.d(y) in order to identify the energy of the incident neutrons. The analysis allows a better estimate of H(*)(10). The aim of this article is to describe the TEPC and the effect of these methods of optimisation.
Key concepts: Proportional counter, Neutron, Equivalent dose, Propane, Physics, Nuclear physics, Neutron monitor, Materials science