Ultrasound Biomicroscopy (UBM plus, model P45, Paradigm(R)): Intraobserver Reproducibility and Agreement of Measurements
Hee Yoon Cho, Roo Min Jun, Kyu Ryong Choi
Abstract
Hee Yoon Cho, Roo Min Jun, Kyu Ryong Choi
Abstract
Purpose: To evaluate intraobserver reproducibility of measurements in images obtained by the ultrasound biomicroscopy (UBM plus, model P45, Paradigm, Inc., Utah, USA) and estimate the agreement of measurements by ultrasound biomicroscopy and A-scan ultrasound (model P37, Paradigm, Inc., Utah, USA). Methods: The anterior segment images of fifteen normal patients were obtained twice by single examiner. Six different parameters were measured in each image. Among the parameters, anterior chamber depth was compared with that measured by A-scan ultrasound. Results: The intraobserver reproducibility was high for all six parameters that includes central corneal thickness (coefficient of variation (%) 2.80), anterior chamber depth (coefficient of variation (%) 1.20), anterior chamber angle (coefficient of variation (%) 4.01), scleral thickness (coefficient of variation (%) 4.28), trabecular meshwork-iris distance (coefficient of variation (%) 6.09) and angle opening distance (AOD500, coefficient of variation (%) 6.09). The correlation between ultrasound biomicroscopy and A-scan ultrasound in measuring the anterior chamber depth was statistically significant (correlation coefficient = 0.79, p=0.002). Conclusions: The measurements of anterior segment parameters by ultrasound biomicroscopy have high reproducibility and will be useful in evaluating the anterior segment structure.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Purpose: To evaluate intraobserver reproducibility of measurements in images obtained by the ultrasound biomicroscopy (UBM plus, model P45, Paradigm, Inc., Utah, USA) and estimate the agreement of measurements by ultrasound biomicroscopy and A-scan ultrasound (model P37, Paradigm, Inc., Utah, USA). Methods: The anterior segment images of fifteen normal patients were obtained twice by single examiner. Six different parameters were measured in each image. Among the parameters, anterior chamber depth was compared with that measured by A-scan ultrasound. Results: The intraobserver reproducibility was high for all six parameters that includes central corneal thickness (coefficient of variation (%) 2.80), anterior chamber depth (coefficient of variation (%) 1.20), anterior chamber angle (coefficient of variation (%) 4.01), scleral thickness (coefficient of variation (%) 4.28), trabecular meshwork-iris distance (coefficient of variation (%) 6.09) and angle opening distance (AOD500, coefficient of variation (%) 6.09). The correlation between ultrasound biomicroscopy and A-scan ultrasound in measuring the anterior chamber depth was statistically significant (correlation coefficient = 0.79, p=0.002). Conclusions: The measurements of anterior segment parameters by ultrasound biomicroscopy have high reproducibility and will be useful in evaluating the anterior segment structure.
Key concepts: Ultrasound biomicroscopy, Reproducibility, Ultrasound, Coefficient of variation, Anterior chamber angle, Medicine, Nuclear medicine, Correlation coefficient