Ultrasound biomicroscopy. III. Accuracy and agreement of measurements

Steen Fiil Urbak

Open full text 41 citations

Abstract

PURPOSE: To estimate the accuracy of measurements by the 50 MHz Humphrey Ultrasound Biomicroscope and evaluate the agreement of measurements by ultrasound biomicroscopy and optical pachometry. METHODS: The accuracy was estimated by comparing measurements by ultrasound biomicroscopy with more exact mechanical methods. Forty-seven PMMA intraocular lenses and 52 distances between horizontal separated sutures were measured. The agreement between ultrasound biomicroscopy and optical pachometry was evaluated by comparing measurements of central cornea thickness and anterior chamber depth of 46 eyes. RESULTS: The axial measurements by ultrasound biomicroscopy was on average 10 microm higher than the reference method (SEM 3 microm). The lateral measurements was without systematic difference from the reference method (SEM 5 microm). The mean central corneal thickness was considerably higher by optical pachometry, 557+/-5 microm (SEM), than by ultrasound biomicroscopy, 533+/-5 microm. Similarly for anterior chamber depth where mean measurements were 2955+/-66 microm and 2897+/-63 microm, respectively. CONCLUSIONS: The axial and lateral accuracy of ultrasound biomicroscopic measurements was good. The agreement between measurements obtained by ultrasound biomicroscopy and optical pachometry was poor in this investigation. Several circumstances could be accountable for this.

Open-access reader

About this research paper

What this paper is about

PURPOSE: To estimate the accuracy of measurements by the 50 MHz Humphrey Ultrasound Biomicroscope and evaluate the agreement of measurements by ultrasound biomicroscopy and optical pachometry. METHODS: The accuracy was estimated by comparing measurements by ultrasound biomicroscopy with more exact mechanical methods. Forty-seven PMMA intraocular lenses and 52 distances between horizontal separated sutures were measured. The agreement between ultrasound biomicroscopy and optical pachometry was evaluated by comparing measurements of central cornea thickness and anterior chamber depth of 46 eyes. RESULTS: The axial measurements by ultrasound biomicroscopy was on average 10 microm higher than the reference method (SEM 3 microm). The lateral measurements was without systematic difference from the reference method (SEM 5 microm). The mean central corneal thickness was considerably higher by optical pachometry, 557+/-5 microm (SEM), than by ultrasound biomicroscopy, 533+/-5 microm. Similarly for anterior chamber depth where mean measurements were 2955+/-66 microm and 2897+/-63 microm, respectively. CONCLUSIONS: The axial and lateral accuracy of ultrasound biomicroscopic measurements was good. The agreement between measurements obtained by ultrasound biomicroscopy and optical pachometry was poor in this investigation. Several circumstances could be accountable for this.

Why it matters

OpenAlex reports 41 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To estimate the accuracy of measurements by the 50 MHz Humphrey Ultrasound Biomicroscope and evaluate the agreement of measurements by ultrasound biomicroscopy and optical pachometry. METHODS: The accuracy was estimated by comparing measurements by ultrasound biomicroscopy with more exact mechanical methods. Forty-seven PMMA intraocular lenses and 52 distances between horizontal separated sutures were measured. The agreement between ultrasound biomicroscopy and optical pachometry was evaluated by comparing measurements of central cornea thickness and anterior chamber depth of 46 eyes. RESULTS: The axial measurements by ultrasound biomicroscopy was on average 10 microm higher than the reference method (SEM 3 microm). The lateral measurements was without systematic difference from the reference method (SEM 5 microm). The mean central corneal thickness was considerably higher by optical pachometry, 557+/-5 microm (SEM), than by ultrasound biomicroscopy, 533+/-5 microm. Similarly for anterior chamber depth where mean measurements were 2955+/-66 microm and 2897+/-63 microm, respectively. CONCLUSIONS: The axial and lateral accuracy of ultrasound biomicroscopic measurements was good. The agreement between measurements obtained by ultrasound biomicroscopy and optical pachometry was poor in this investigation. Several circumstances could be accountable for this.

Key concepts: Ultrasound biomicroscopy, Citation, Medicine, Library science, Ophthalmology, Optometry, Ultrasound, Computer science