2011Asian Journal of Research in ChemistryRequires access

Development of RP-HPLC Method for Simultaneous Estimation of Amlodipine and Ramipril in Tablet Dosage form.

Meenaxi M. Maste, M.C. Kalekar, Naveen Kadian, A. R. Bhat

Open publisher page 2 citations

Abstract

Present work describes a precise, accurate and reproducible Reverse phase High Performance Liquid Chromatographic (RP-HPLC) method for simultaneous estimation of Ramipril and Amlodipine in tablet dosage form on Phenomenex C18 column (245 mm × 4.5 mm, 5 μm, particle size) using acetonitrile: phosphatebuffer, (60:40 v/v) as mobile phase at flow rate of 1.0 ml/min and the detection wavelength was 222 nm. The retention time for Ramipril and Amlodipine was found to be 3.41 and 6.10 min respectively. Proposed method was validated for precision, accuracy, linearity range, robustness and ruggedness.

About this research paper

What this paper is about

Present work describes a precise, accurate and reproducible Reverse phase High Performance Liquid Chromatographic (RP-HPLC) method for simultaneous estimation of Ramipril and Amlodipine in tablet dosage form on Phenomenex C18 column (245 mm × 4.5 mm, 5 μm, particle size) using acetonitrile: phosphatebuffer, (60:40 v/v) as mobile phase at flow rate of 1.0 ml/min and the detection wavelength was 222 nm. The retention time for Ramipril and Amlodipine was found to be 3.41 and 6.10 min respectively. Proposed method was validated for precision, accuracy, linearity range, robustness and ruggedness.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Present work describes a precise, accurate and reproducible Reverse phase High Performance Liquid Chromatographic (RP-HPLC) method for simultaneous estimation of Ramipril and Amlodipine in tablet dosage form on Phenomenex C18 column (245 mm × 4.5 mm, 5 μm, particle size) using acetonitrile: phosphatebuffer, (60:40 v/v) as mobile phase at flow rate of 1.0 ml/min and the detection wavelength was 222 nm. The retention time for Ramipril and Amlodipine was found to be 3.41 and 6.10 min respectively. Proposed method was validated for precision, accuracy, linearity range, robustness and ruggedness.

Key concepts: Amlodipine, Ramipril, Chromatography, Dosage form, Particle size, Acetonitrile, Materials science, High-performance liquid chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Development of RP-HPLC Method for Simultaneous Estimation of Amlodipine and Ramipril in Tablet Dosage form. — Research Paper | ScholarLens