2009Yaowu fenxi zazhiRequires access

HPLC determination of chlorogenic acid in dandelion extract

Hongmei Li, Xin Zhang, Chang Dong-sheng

Open publisher page 0 citations

Abstract

Objective:To establish an HPLC method for the determination of chlorogenic acid in dandelion extract.Methods:Agilent Zorbax SB C18 column(4.6 mm×250 mm,5 μm) was adopted;The mobile phase consisted of acetonitrile-0.4% phosphoric acid solution(10∶90)at a flow rate of 1.0 mL·min-1;The detection wavelength was set at 324 nm,and column temperature was 30 ℃.Results:The linear ranges of chlorogenic acid was 0.040-0.60 μg(r=0.9992);The average recoveriey(n=5) was 96.48%.Conclusion:HPLC determination of chlorogenic acid in dandelion extract is rapid,simple and accurate.It can be applied to determine of chlorogenic acid in dandelion extract.

About this research paper

What this paper is about

Objective:To establish an HPLC method for the determination of chlorogenic acid in dandelion extract.Methods:Agilent Zorbax SB C18 column(4.6 mm×250 mm,5 μm) was adopted;The mobile phase consisted of acetonitrile-0.4% phosphoric acid solution(10∶90)at a flow rate of 1.0 mL·min-1;The detection wavelength was set at 324 nm,and column temperature was 30 ℃.Results:The linear ranges of chlorogenic acid was 0.040-0.60 μg(r=0.9992);The average recoveriey(n=5) was 96.48%.Conclusion:HPLC determination of chlorogenic acid in dandelion extract is rapid,simple and accurate.It can be applied to determine of chlorogenic acid in dandelion extract.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish an HPLC method for the determination of chlorogenic acid in dandelion extract.Methods:Agilent Zorbax SB C18 column(4.6 mm×250 mm,5 μm) was adopted;The mobile phase consisted of acetonitrile-0.4% phosphoric acid solution(10∶90)at a flow rate of 1.0 mL·min-1;The detection wavelength was set at 324 nm,and column temperature was 30 ℃.Results:The linear ranges of chlorogenic acid was 0.040-0.60 μg(r=0.9992);The average recoveriey(n=5) was 96.48%.Conclusion:HPLC determination of chlorogenic acid in dandelion extract is rapid,simple and accurate.It can be applied to determine of chlorogenic acid in dandelion extract.

Key concepts: Chlorogenic acid, Dandelion, Chemistry, Chromatography, Phosphoric acid, High-performance liquid chromatography, Organic chemistry, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
HPLC determination of chlorogenic acid in dandelion extract — Research Paper | ScholarLens