2015Indian Journal of Pharmacy and PharmacologyRequires access

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF NIACIN AND SIMVASTATIN IN TABLET DOSAGE

Anil P. Dewani, D. S. Mohale, Sanket Dadarao Hiware, Ravindra L. Bakal, A. V. Chandewar

Open publisher page 3 citations

Abstract

This work is concerned with application of simple, accurate, precise and highly selective reverse phase high performance liquid chromatographic (RP-HPLC) method for simultaneous estimation of Niacin (NA) and Simvastatin (SIM) in combined dosage form. Chromatographic separation was achieved by isocratic mode using a reverse phase C18 column (phenomenx, 150 × 4.6 mm i.d.). The mobile phase composed methanol: water in ratio 85:15 water consisting of Triethylamine (TEA) (0.05%v/v) v/v at flow rate of 1 ml/min pH was adjusted to 4 with orthophosporic acid. Detection was carried out using a UV-vis detector at 250 nm. The mean retention time of NA and SIM was found to be 1.8 min and 8.5 min. respectively. The method was found to be linear in the range of 80–120 μg/ml with mean recovery of 99.39% for NA and 99.18% for SIM. The correlation coefficients for both NA and SIM were close to 1. The developed method was validated according to ICH guidelines and values of accuracy, precision and other statistical analysis were found to be in good accordance with the prescribed values. Thus the proposed method was successfully applied for simultaneous determination of NA and SIM in routine analysis of formulation.

About this research paper

What this paper is about

This work is concerned with application of simple, accurate, precise and highly selective reverse phase high performance liquid chromatographic (RP-HPLC) method for simultaneous estimation of Niacin (NA) and Simvastatin (SIM) in combined dosage form. Chromatographic separation was achieved by isocratic mode using a reverse phase C18 column (phenomenx, 150 × 4.6 mm i.d.). The mobile phase composed methanol: water in ratio 85:15 water consisting of Triethylamine (TEA) (0.05%v/v) v/v at flow rate of 1 ml/min pH was adjusted to 4 with orthophosporic acid. Detection was carried out using a UV-vis detector at 250 nm. The mean retention time of NA and SIM was found to be 1.8 min and 8.5 min. respectively. The method was found to be linear in the range of 80–120 μg/ml with mean recovery of 99.39% for NA and 99.18% for SIM. The correlation coefficients for both NA and SIM were close to 1. The developed method was validated according to ICH guidelines and values of accuracy, precision and other statistical analysis were found to be in good accordance with the prescribed values. Thus the proposed method was successfully applied for simultaneous determination of NA and SIM in routine analysis of formulation.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This work is concerned with application of simple, accurate, precise and highly selective reverse phase high performance liquid chromatographic (RP-HPLC) method for simultaneous estimation of Niacin (NA) and Simvastatin (SIM) in combined dosage form. Chromatographic separation was achieved by isocratic mode using a reverse phase C18 column (phenomenx, 150 × 4.6 mm i.d.). The mobile phase composed methanol: water in ratio 85:15 water consisting of Triethylamine (TEA) (0.05%v/v) v/v at flow rate of 1 ml/min pH was adjusted to 4 with orthophosporic acid. Detection was carried out using a UV-vis detector at 250 nm. The mean retention time of NA and SIM was found to be 1.8 min and 8.5 min. respectively. The method was found to be linear in the range of 80–120 μg/ml with mean recovery of 99.39% for NA and 99.18% for SIM. The correlation coefficients for both NA and SIM were close to 1. The developed method was validated according to ICH guidelines and values of accuracy, precision and other statistical analysis were found to be in good accordance with the prescribed values. Thus the proposed method was successfully applied for simultaneous determination of NA and SIM in routine analysis of formulation.

Key concepts: Chromatography, Simvastatin, Dosage form, Triethylamine, High-performance liquid chromatography, Chemistry, Methanol, Phase (matter)

Related papers

Back to paper searchBrowse research topicsOriginal source
DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF NIACIN AND SIMVASTATIN IN TABLET DOSAGE — Research Paper | ScholarLens