The prime aim of the current work is to develop and validate a novel, sensitive, reverse phase High Performance Liquid Chromatography (RP-HPLC) technique for the estimation of Glibenclamide in dosage form. Chromatographic separation was achieved on a Chromosil column, (150mm×4.6mm x5μ) using an isocratic method with mobile phase composed of Potassium di-hydrogen phosphate buffer (pH 4.5): Acetonitrile in the ratio 60:40 v/v. The flow rate was 1 ml/min, temperature of the column was maintained at ambient and detection was made at 233 nm. The run time was 12 min. The developed method was validated according to the International Conference on Harmonization (ICH) guidelines with respect to linearity, accuracy, precision, specificity and robustness. The developed method was linear for Glibenclamide from 10 -50 μg/ml and the linear regression obtained was > 0.999. Precision, evaluated by intraand inter-day assays had relative standard deviation (R.S.D) values within 1.5%. Recovery data were in the range 98.2% to 100.9% with R.S.D. values < 1.5%. The method is precise, accurate, linear, robust and fast. The short retention time allows the analysis of a large number of samples in a short period of time and, therefore, should be costeffective for routine Quality Control in the pharmaceutical industry.

About this research paper

What this paper is about

The prime aim of the current work is to develop and validate a novel, sensitive, reverse phase High Performance Liquid Chromatography (RP-HPLC) technique for the estimation of Glibenclamide in dosage form. Chromatographic separation was achieved on a Chromosil column, (150mm×4.6mm x5μ) using an isocratic method with mobile phase composed of Potassium di-hydrogen phosphate buffer (pH 4.5): Acetonitrile in the ratio 60:40 v/v. The flow rate was 1 ml/min, temperature of the column was maintained at ambient and detection was made at 233 nm. The run time was 12 min. The developed method was validated according to the International Conference on Harmonization (ICH) guidelines with respect to linearity, accuracy, precision, specificity and robustness. The developed method was linear for Glibenclamide from 10 -50 μg/ml and the linear regression obtained was > 0.999. Precision, evaluated by intraand inter-day assays had relative standard deviation (R.S.D) values within 1.5%. Recovery data were in the range 98.2% to 100.9% with R.S.D. values < 1.5%. The method is precise, accurate, linear, robust and fast. The short retention time allows the analysis of a large number of samples in a short period of time and, therefore, should be costeffective for routine Quality Control in the pharmaceutical industry.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The prime aim of the current work is to develop and validate a novel, sensitive, reverse phase High Performance Liquid Chromatography (RP-HPLC) technique for the estimation of Glibenclamide in dosage form. Chromatographic separation was achieved on a Chromosil column, (150mm×4.6mm x5μ) using an isocratic method with mobile phase composed of Potassium di-hydrogen phosphate buffer (pH 4.5): Acetonitrile in the ratio 60:40 v/v. The flow rate was 1 ml/min, temperature of the column was maintained at ambient and detection was made at 233 nm. The run time was 12 min. The developed method was validated according to the International Conference on Harmonization (ICH) guidelines with respect to linearity, accuracy, precision, specificity and robustness. The developed method was linear for Glibenclamide from 10 -50 μg/ml and the linear regression obtained was > 0.999. Precision, evaluated by intraand inter-day assays had relative standard deviation (R.S.D) values within 1.5%. Recovery data were in the range 98.2% to 100.9% with R.S.D. values < 1.5%. The method is precise, accurate, linear, robust and fast. The short retention time allows the analysis of a large number of samples in a short period of time and, therefore, should be costeffective for routine Quality Control in the pharmaceutical industry.

Key concepts: Glibenclamide, Chromatography, Retention time, Dosage form, Acetonitrile, Linearity, Linear regression, High-performance liquid chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
RP-HPLC method development and validation for estimation of Glibenclamide in tablet dosage form — Research Paper | ScholarLens