RP-HPLC Method for Simultaneous Estimation of Simvastatin and Ezetimibe in Bulk Drug and its Combined Dosage Form.
Nilesh Kumar Jain, Surendra Jain, Hemant Swami, Surendra Jain
Abstract
Nilesh Kumar Jain, Surendra Jain, Hemant Swami, Surendra Jain
Abstract
This work is concerned with application of simple, accurate, precise and highly selective reverse phase high performance liquid chromatographic (RP-HPLC) method for simultaneous estimation of simvastatin and ezetimibe in combined dosage form. Chromatographic separation was achieved isocratically at 25°C ± 0.5°C on Luna C18 column (250 х 4.6 mm i.d.) with a mobile phase composed of methanol: water: acetonitrile in the ratio of 75: 18.75: 6.25 % v/v/v at flow rate of 1.8 ml/min. Detection is carried out using a UV-PDA detector at 231 nm. The retention time of simvastatin and ezetimibe was found to be 13.5 + 0.5 min and 4.02 + 0.3 min. respectively. The method was found to be linear in the range of 1-50 μg/ml with mean recovery of 99.21% for simvastatin and 99.50% for ezetimibe. The correlation coefficients for all components are close to 1. The developed method was validated according to ICH guidelines and values of accuracy, precision and other statistical analysis were found to be in good accordance with the prescribed values. Thus the proposed method was successfully applied for simultaneous determination of simvastatin and ezetimibe in routine analysis.
OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This work is concerned with application of simple, accurate, precise and highly selective reverse phase high performance liquid chromatographic (RP-HPLC) method for simultaneous estimation of simvastatin and ezetimibe in combined dosage form. Chromatographic separation was achieved isocratically at 25°C ± 0.5°C on Luna C18 column (250 х 4.6 mm i.d.) with a mobile phase composed of methanol: water: acetonitrile in the ratio of 75: 18.75: 6.25 % v/v/v at flow rate of 1.8 ml/min. Detection is carried out using a UV-PDA detector at 231 nm. The retention time of simvastatin and ezetimibe was found to be 13.5 + 0.5 min and 4.02 + 0.3 min. respectively. The method was found to be linear in the range of 1-50 μg/ml with mean recovery of 99.21% for simvastatin and 99.50% for ezetimibe. The correlation coefficients for all components are close to 1. The developed method was validated according to ICH guidelines and values of accuracy, precision and other statistical analysis were found to be in good accordance with the prescribed values. Thus the proposed method was successfully applied for simultaneous determination of simvastatin and ezetimibe in routine analysis.
Key concepts: Ezetimibe, Simvastatin, Chromatography, Dosage form, Chemistry, High-performance liquid chromatography, Chromatographic separation, Methanol