2010Shijie zhongxiyi jiehe zazhiRequires access

Determination of baicalin in Anfei capsule by HPLC.

Xiangping Pei, Shurong Zhang, Pei Miao-rong, Yufeng Yang, Haifeng Wang

Open publisher page 0 citations

Abstract

Objective To determine the content of baicalin in Anfei capsule by HPLC.Methods Chromatographic column:Diamonsil C18 column(4.6 mm×150 mm,5 μm);mobile phase:methol-water-phosphoric acid(47∶52∶0.2);flow rate:1.0 mL·min-1;detection wavelength:280 nm;column temperature:ambient temperature.Results The linear relation of baicalin was good in the range from 7.5 μg to 60 μg.Regression equation:y=63.482x+0.644 7;r=0.999 5.Average recovery was 99.8%.Conclusion The method is simple,rapid and accurate in operation and it is suitable for the determination of content of baicalin in Anfei capsule.

About this research paper

What this paper is about

Objective To determine the content of baicalin in Anfei capsule by HPLC.Methods Chromatographic column:Diamonsil C18 column(4.6 mm×150 mm,5 μm);mobile phase:methol-water-phosphoric acid(47∶52∶0.2);flow rate:1.0 mL·min-1;detection wavelength:280 nm;column temperature:ambient temperature.Results The linear relation of baicalin was good in the range from 7.5 μg to 60 μg.Regression equation:y=63.482x+0.644 7;r=0.999 5.Average recovery was 99.8%.Conclusion The method is simple,rapid and accurate in operation and it is suitable for the determination of content of baicalin in Anfei capsule.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To determine the content of baicalin in Anfei capsule by HPLC.Methods Chromatographic column:Diamonsil C18 column(4.6 mm×150 mm,5 μm);mobile phase:methol-water-phosphoric acid(47∶52∶0.2);flow rate:1.0 mL·min-1;detection wavelength:280 nm;column temperature:ambient temperature.Results The linear relation of baicalin was good in the range from 7.5 μg to 60 μg.Regression equation:y=63.482x+0.644 7;r=0.999 5.Average recovery was 99.8%.Conclusion The method is simple,rapid and accurate in operation and it is suitable for the determination of content of baicalin in Anfei capsule.

Key concepts: Baicalin, Chromatography, Capsule, Phosphoric acid, High-performance liquid chromatography, Content determination, Linear range, Medicine