2008American Journal of RoentgenologyRequires access

Perfusion CT of the Brain Using 40-mm-Wide Detector and Toggling Table Technique for Initial Imaging of Acute Stroke

Sung Won Youn, Jae Hyoung Kim, Young-Cheol Weon, Sung Hyun Kim, Moon‐Ku Han, Hee‐Joon Bae

Open publisher page 59 citations

Abstract

OBJECTIVE: Limited coverage of the brain in the z-axis has been a drawback of perfusion CT. The purpose of this study was to evaluate the usefulness of perfusion CT with extended coverage in the z-axis for the assessment of acute stroke in an emergent clinical setting. MATERIALS AND METHODS: Fifty-eight patients who underwent 80-mm-coverage perfusion CT within 24 hours after stroke onset were included. Perfusion CT was performed using a 64-MDCT unit equipped with 40-mm-wide detector and the toggling table technique. Lesion detection by perfusion CT was analyzed using follow-up diffusion-weighted imaging and MR angiography as the reference standards. More conventional 20-mm-coverage perfusion CT was simulated by extracting data obtained at the basal ganglia level for comparison with 80-mm-coverage perfusion CT. RESULTS: Fifty-one patients had acute infarctions and seven patients did not. For 80-mm-coverage perfusion CT, perfusion abnormality was detected in 42 of 51 patients (sensitivity, 82.4%; and specificity, 85.7%). When patients with small artery disease (small acute infarctions in the basal ganglia, thalamus, corona radiata, and pons) were excluded, sensitivity increased to 92.3%. As compared with 80-mm-coverage perfusion CT, 20-mm-coverage perfusion CT missed nine acute infarctions located above or below the level of the basal ganglia (p = 0.0039). CONCLUSION: Perfusion CT with 80-mm-coverage was found to be useful as an initial imaging method in acute ischemic stroke, although it had low sensitivity for detecting small acute infarctions. In particular, this technique provided higher lesion detection than 20-mm-coverage perfusion CT.

About this research paper

What this paper is about

OBJECTIVE: Limited coverage of the brain in the z-axis has been a drawback of perfusion CT. The purpose of this study was to evaluate the usefulness of perfusion CT with extended coverage in the z-axis for the assessment of acute stroke in an emergent clinical setting. MATERIALS AND METHODS: Fifty-eight patients who underwent 80-mm-coverage perfusion CT within 24 hours after stroke onset were included. Perfusion CT was performed using a 64-MDCT unit equipped with 40-mm-wide detector and the toggling table technique. Lesion detection by perfusion CT was analyzed using follow-up diffusion-weighted imaging and MR angiography as the reference standards. More conventional 20-mm-coverage perfusion CT was simulated by extracting data obtained at the basal ganglia level for comparison with 80-mm-coverage perfusion CT. RESULTS: Fifty-one patients had acute infarctions and seven patients did not. For 80-mm-coverage perfusion CT, perfusion abnormality was detected in 42 of 51 patients (sensitivity, 82.4%; and specificity, 85.7%). When patients with small artery disease (small acute infarctions in the basal ganglia, thalamus, corona radiata, and pons) were excluded, sensitivity increased to 92.3%. As compared with 80-mm-coverage perfusion CT, 20-mm-coverage perfusion CT missed nine acute infarctions located above or below the level of the basal ganglia (p = 0.0039). CONCLUSION: Perfusion CT with 80-mm-coverage was found to be useful as an initial imaging method in acute ischemic stroke, although it had low sensitivity for detecting small acute infarctions. In particular, this technique provided higher lesion detection than 20-mm-coverage perfusion CT.

Why it matters

OpenAlex reports 59 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: Limited coverage of the brain in the z-axis has been a drawback of perfusion CT. The purpose of this study was to evaluate the usefulness of perfusion CT with extended coverage in the z-axis for the assessment of acute stroke in an emergent clinical setting. MATERIALS AND METHODS: Fifty-eight patients who underwent 80-mm-coverage perfusion CT within 24 hours after stroke onset were included. Perfusion CT was performed using a 64-MDCT unit equipped with 40-mm-wide detector and the toggling table technique. Lesion detection by perfusion CT was analyzed using follow-up diffusion-weighted imaging and MR angiography as the reference standards. More conventional 20-mm-coverage perfusion CT was simulated by extracting data obtained at the basal ganglia level for comparison with 80-mm-coverage perfusion CT. RESULTS: Fifty-one patients had acute infarctions and seven patients did not. For 80-mm-coverage perfusion CT, perfusion abnormality was detected in 42 of 51 patients (sensitivity, 82.4%; and specificity, 85.7%). When patients with small artery disease (small acute infarctions in the basal ganglia, thalamus, corona radiata, and pons) were excluded, sensitivity increased to 92.3%. As compared with 80-mm-coverage perfusion CT, 20-mm-coverage perfusion CT missed nine acute infarctions located above or below the level of the basal ganglia (p = 0.0039). CONCLUSION: Perfusion CT with 80-mm-coverage was found to be useful as an initial imaging method in acute ischemic stroke, although it had low sensitivity for detecting small acute infarctions. In particular, this technique provided higher lesion detection than 20-mm-coverage perfusion CT.

Key concepts: Medicine, Perfusion scanning, Acute stroke, Perfusion, Table (database), Detector, Stroke (engine), Nuclear medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Perfusion CT of the Brain Using 40-mm-Wide Detector and Toggling Table Technique for Initial Imaging of Acute Stroke — Research Paper | ScholarLens