2011The Proceedings of the International Conference on Nuclear Engineering (ICONE)Open access

ICONE19-43754 RETRAN Analysis of Feedwater Controller Failure Transient for Lungmen ABWR

Wen‐Hsiung Wu, Jong-Rong Wang, Chunkuan Shih, Yng-Ruey Yuann

Open full text 0 citations

Abstract

This study used RETRAN-3D program to analyze the FWCFWB transient at 100% rated power/111% rated core flow and under EOC operating condition where the ΔCPR response was worst. Important system operational actions included (1) the turbine and the feedwater pumps tripped on high water level (L8), (2) fast bypass valves opening which inhibited reactor scram and RIPs trip on turbine trip, (3) reactor scram and the four RIPs which are not connected to the Motor Generator (M-G) sets tripped on low water level (L3), (4) low-low water level (L2) initiation of the Reactor Core Isolation Cooling System (RCIC). The ΔCPR of this event was 0.05 and the results were compared with those from FSAR. It showed that there was a significant difference in the change rate of vessel water level, but other transient trends were in good agreement with FSAR. A test of all bypass valves failed to open was also covered in this study. In this situation, the reactor scram occurred on high water level turbine trip, and the ΔCPR would rise to 0.17.

Open-access reader

About this research paper

What this paper is about

This study used RETRAN-3D program to analyze the FWCFWB transient at 100% rated power/111% rated core flow and under EOC operating condition where the ΔCPR response was worst. Important system operational actions included (1) the turbine and the feedwater pumps tripped on high water level (L8), (2) fast bypass valves opening which inhibited reactor scram and RIPs trip on turbine trip, (3) reactor scram and the four RIPs which are not connected to the Motor Generator (M-G) sets tripped on low water level (L3), (4) low-low water level (L2) initiation of the Reactor Core Isolation Cooling System (RCIC). The ΔCPR of this event was 0.05 and the results were compared with those from FSAR. It showed that there was a significant difference in the change rate of vessel water level, but other transient trends were in good agreement with FSAR. A test of all bypass valves failed to open was also covered in this study. In this situation, the reactor scram occurred on high water level turbine trip, and the ΔCPR would rise to 0.17.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study used RETRAN-3D program to analyze the FWCFWB transient at 100% rated power/111% rated core flow and under EOC operating condition where the ΔCPR response was worst. Important system operational actions included (1) the turbine and the feedwater pumps tripped on high water level (L8), (2) fast bypass valves opening which inhibited reactor scram and RIPs trip on turbine trip, (3) reactor scram and the four RIPs which are not connected to the Motor Generator (M-G) sets tripped on low water level (L3), (4) low-low water level (L2) initiation of the Reactor Core Isolation Cooling System (RCIC). The ΔCPR of this event was 0.05 and the results were compared with those from FSAR. It showed that there was a significant difference in the change rate of vessel water level, but other transient trends were in good agreement with FSAR. A test of all bypass valves failed to open was also covered in this study. In this situation, the reactor scram occurred on high water level turbine trip, and the ΔCPR would rise to 0.17.

Key concepts: Scram, Boiler feedwater, Shutdown, Turbine, Nuclear engineering, Transient (computer programming), Boiling water reactor, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
ICONE19-43754 RETRAN Analysis of Feedwater Controller Failure Transient for Lungmen ABWR — Research Paper | ScholarLens