2013•Journal of Chromatographic ScienceRequires access

HPLC Method with Solid-Phase Extraction for Determination of (R)- and (S)-Ketoprofen in Plasma without Caffeine Interference: Application to Pharmacokinetic Studies in Rats

Francisco Javier López‐Muñoz, Nancy Vara Gama, Olivia Soria‐Arteche, Marcela Hurtado y de la Peña, Adriana Miriam Domínguez‐Ramírez, José Raúl Medina López

Open publisher page 7 citations

Abstract

A fast and reproducible high-performance liquid chromatography method has been developed for the determination of (R)- and (S)-ketoprofen. Ketoprofen enantiomers were determined in plasma samples (50 µL), after solid-phase extraction, using diclofenac as internal standard. Analyses were performed on a (S, S)-Whelk-O 1 stainless steel column (5 µm, 250 × 4.6 mm) using hexane-ethanol-acetic acid (93:7:0.5, v/v/v) as the mobile phase and detection at 254 nm. The method was selective for ketoprofen enantiomers in the presence of caffeine and endogenous plasma compounds. Standard curves were linear (R(2) > 0.999) over the concentration range of 0.25-12.50 and 0.25 µg/mL was taken as the limit of quantification. The intra- and interday precision (relative standard deviation) values were <15.0% and the accuracy (relative error) was within ±12.0% at 1.0, 5.0 and 10.0 µg/mL. Enantiomer recoveries yielded 100.0 ± 15%. No significant differences were determined in plasma samples stored at room temperature for 24.0 h, after two freeze-thaw cycles, and between 0 and 4 weeks at -20°C (P > 0.05). The validated method was successfully applied in determination of (S)-ketoprofen in Wistar rats after oral administration of 3.2 mg/kg of (S)-ketoprofen alone or 3.2 mg/kg of (S)-ketoprofen + 17.8 mg/kg of caffeine.

About this research paper

What this paper is about

A fast and reproducible high-performance liquid chromatography method has been developed for the determination of (R)- and (S)-ketoprofen. Ketoprofen enantiomers were determined in plasma samples (50 µL), after solid-phase extraction, using diclofenac as internal standard. Analyses were performed on a (S, S)-Whelk-O 1 stainless steel column (5 µm, 250 × 4.6 mm) using hexane-ethanol-acetic acid (93:7:0.5, v/v/v) as the mobile phase and detection at 254 nm. The method was selective for ketoprofen enantiomers in the presence of caffeine and endogenous plasma compounds. Standard curves were linear (R(2) > 0.999) over the concentration range of 0.25-12.50 and 0.25 µg/mL was taken as the limit of quantification. The intra- and interday precision (relative standard deviation) values were <15.0% and the accuracy (relative error) was within ±12.0% at 1.0, 5.0 and 10.0 µg/mL. Enantiomer recoveries yielded 100.0 ± 15%. No significant differences were determined in plasma samples stored at room temperature for 24.0 h, after two freeze-thaw cycles, and between 0 and 4 weeks at -20°C (P > 0.05). The validated method was successfully applied in determination of (S)-ketoprofen in Wistar rats after oral administration of 3.2 mg/kg of (S)-ketoprofen alone or 3.2 mg/kg of (S)-ketoprofen + 17.8 mg/kg of caffeine.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A fast and reproducible high-performance liquid chromatography method has been developed for the determination of (R)- and (S)-ketoprofen. Ketoprofen enantiomers were determined in plasma samples (50 µL), after solid-phase extraction, using diclofenac as internal standard. Analyses were performed on a (S, S)-Whelk-O 1 stainless steel column (5 µm, 250 × 4.6 mm) using hexane-ethanol-acetic acid (93:7:0.5, v/v/v) as the mobile phase and detection at 254 nm. The method was selective for ketoprofen enantiomers in the presence of caffeine and endogenous plasma compounds. Standard curves were linear (R(2) > 0.999) over the concentration range of 0.25-12.50 and 0.25 µg/mL was taken as the limit of quantification. The intra- and interday precision (relative standard deviation) values were <15.0% and the accuracy (relative error) was within ±12.0% at 1.0, 5.0 and 10.0 µg/mL. Enantiomer recoveries yielded 100.0 ± 15%. No significant differences were determined in plasma samples stored at room temperature for 24.0 h, after two freeze-thaw cycles, and between 0 and 4 weeks at -20°C (P > 0.05). The validated method was successfully applied in determination of (S)-ketoprofen in Wistar rats after oral administration of 3.2 mg/kg of (S)-ketoprofen alone or 3.2 mg/kg of (S)-ketoprofen + 17.8 mg/kg of caffeine.

Key concepts: Ketoprofen, Chemistry, Chromatography, Pharmacokinetics, High-performance liquid chromatography, Enantiomer, Detection limit, Caffeine

Related papers

Back to paper searchBrowse research topicsOriginal source
HPLC Method with Solid-Phase Extraction for Determination of (R)- and (S)-Ketoprofen in Plasma without Caffeine Interference: Application to Pharmacokinetic Studies in Rats — Research Paper | ScholarLens